Optimization and Validation of the SBSE–HPLC–FLD Method for the Determination of Priority Pollutants PAHs in Several Water Matrices

Polycyclic aromatic hydrocarbons (PAHs) are priority pollutants in drinking and environmental waters. Their mutagenic/carcinogenic potential and ng·L<sup>- 1</sup> limits demand methods that are both sensitive and practical. We report a rapid, solvent-sparing workflow coupling stir-bar sorptive extraction (SBSE) to HPLC with fluorescence detection (FLD) for simultaneous determination of six PAHs (fluoranthene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene) in drinking water, groundwater, and surface water. SBSE conditions were optimized, and isocratic RP-HPLC achieved baseline resolution within a 26-min cycle using ~ 39 mL solvent (~ 20 samples day - 1). Validation under ISO/IEC 17,025 showed linear calibration (r ≥ 0.99941), limits of detection of 0.4-1.8 ng·L<sup>- 1</sup>, and matrix-verified LOQs of 1.5-10.9 ng·L<sup>- 1</sup>. Trueness and precision met predefined criteria across matrices (recoveries 63.3-109.9%; within-laboratory reproducibility ≤ 25% RSD), with expanded uncertainties U(k = 2) ≤ 47.1%. Performance satisfies EU Drinking Water Directive 2020/2184 requirements for benzo[a]pyrene and the regulated PAH sum. By attaining sub-10 ng·L<sup>- 1</sup> LOQs with FLD alone and documenting a complete uncertainty budget, this procedure offers a cost-effective alternative to LC-MS/MS for routine compliance and surveillance. The validated SBSE-HPLC-FLD protocol is fit-for-purpose for regulatory laboratories and environmental services requiring sensitive, robust, and scalable PAH determination across diverse water matrices.

Authors

Institutions

Publication Details

Journal
Archives of Environmental Contamination and Toxicology
Published
2026-02-01
DOI
https://doi.org/10.1007/s00244-026-01183-8
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization and Validation of the SBSE–HPLC–FLD Method for the Determination of Priority Pollutants PAHs in Several Water Matrices

Juliana Garcia, Maria José Alves, Cosme Moura, Eduardo Fernandes-Lage
Archives of Environmental Contamination and Toxicology
Analytical chemistry methods development
article

Optimization and Validation of the SBSE–HPLC–FLD Method for the Determination of Priority Pollutants PAHs in Several Water Matrices

Juliana Garcia, Maria José Alves, Cosme Moura, Eduardo Fernandes-Lage
article en

Abstract

Polycyclic aromatic hydrocarbons (PAHs) are priority pollutants in drinking and environmental waters. Their mutagenic/carcinogenic potential and ng·L<sup>- 1</sup> limits demand methods that are both sensitive and practical. We report a rapid, solvent-sparing workflow coupling stir-bar sorptive extraction (SBSE) to HPLC with fluorescence detection (FLD) for simultaneous determination of six PAHs (fluoranthene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, benzo[ghi]perylene, indeno[1,2,3-cd]pyrene) in drinking water, groundwater, and surface water. SBSE conditions were optimized, and isocratic RP-HPLC achieved baseline resolution within a 26-min cycle using ~ 39 mL solvent (~ 20 samples day - 1). Validation under ISO/IEC 17,025 showed linear calibration (r ≥ 0.99941), limits of detection of 0.4-1.8 ng·L<sup>- 1</sup>, and matrix-verified LOQs of 1.5-10.9 ng·L<sup>- 1</sup>. Trueness and precision met predefined criteria across matrices (recoveries 63.3-109.9%; within-laboratory reproducibility ≤ 25% RSD), with expanded uncertainties U(k = 2) ≤ 47.1%. Performance satisfies EU Drinking Water Directive 2020/2184 requirements for benzo[a]pyrene and the regulated PAH sum. By attaining sub-10 ng·L<sup>- 1</sup> LOQs with FLD alone and documenting a complete uncertainty budget, this procedure offers a cost-effective alternative to LC-MS/MS for routine compliance and surveillance. The validated SBSE-HPLC-FLD protocol is fit-for-purpose for regulatory laboratories and environmental services requiring sensitive, robust, and scalable PAH determination across diverse water matrices.

Archives of Environmental Contamination and ToxicologyVol. 90(2)
University of Trás-os-Montes and Alto Douro (PT), Universidade do Porto (PT), Universidade Politécnica de Bragança (PT), Rede de Química e Tecnologia (PT), Águas de Portugal (Portugal) (PT)
Fundação para a Ciência e a Tecnologia
Clean water and sanitation
Openalex Percentile: Top 57%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.