Comparison of the Dynamic Cut‐Out Failure Modes of Common Proximal Femoral Fixation Devices Using a Mesh‐Free Computational Method

Migration and cut-out are commo n failures observed in internal fixation of intertrochanteric fractures. This study compares the performance of four typical devices under dynamic loading using benchtop and computer-simulated fracture models. The dynamic hip screw (DHS), Gamma3, proximal femoral nail anti-rotation (PFNA-II), and TFN-Advanced (TFNA) were inserted into a solid rigid 10 pounds per cubic foot (PCF) polyurethane bone foam mimicking a reduced unstable intertrochanteric fracture model. Static and dynamic loading tests using a double-peak loading curve based on natural walking gait were conducted. The blade devices had higher resistance to the onset of implant migration under physical dynamic loading in comparison to the screw devices. However, as dynamic loading progressed, no implant showed clear superior performance. Mesh-free simulations of the physical tests were then conducted to visualize stress and failure patterns within the bone foam during migration and cut-out, using an experimentally validated porous foam material model. The mean concordance correlation coefficient between load to cut-out for the physical and simulated tests was 0.953 and 0.858 under static and dynamic loading, respectively. Under simulated dynamic loading, the volumes of yielding and failed bone foam were 15%, 32%, and 25% higher for Gamma3, PFNA-II, and TFNA than for DHS, suggesting that devices with similar forces at cut-out may produce relatively large differences in the volume of damaged bone tissue. Accurate simulation of material damage during dynamic loading may offer a useful alternative method for differentiating device performance in support of clinical decision-making around implant selection.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Research®
Published
2026-02-01
DOI
https://doi.org/10.1002/jor.70159
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the Dynamic Cut‐Out Failure Modes of Common Proximal Femoral Fixation Devices Using a Mesh‐Free Computational Method

Sloan Kulper, Leung Fk, Marilyn Janice Oentaryo, Katie Whiffin et al.
Journal of Orthopaedic Research®
Hip and Femur Fractures
article

Comparison of the Dynamic Cut‐Out Failure Modes of Common Proximal Femoral Fixation Devices Using a Mesh‐Free Computational Method

Sloan Kulper, Leung Fk, Marilyn Janice Oentaryo, Katie Whiffin, Christian X. Fang, Erica Ueda Boles, Kerstin Schneider
article en

Abstract

Migration and cut-out are commo n failures observed in internal fixation of intertrochanteric fractures. This study compares the performance of four typical devices under dynamic loading using benchtop and computer-simulated fracture models. The dynamic hip screw (DHS), Gamma3, proximal femoral nail anti-rotation (PFNA-II), and TFN-Advanced (TFNA) were inserted into a solid rigid 10 pounds per cubic foot (PCF) polyurethane bone foam mimicking a reduced unstable intertrochanteric fracture model. Static and dynamic loading tests using a double-peak loading curve based on natural walking gait were conducted. The blade devices had higher resistance to the onset of implant migration under physical dynamic loading in comparison to the screw devices. However, as dynamic loading progressed, no implant showed clear superior performance. Mesh-free simulations of the physical tests were then conducted to visualize stress and failure patterns within the bone foam during migration and cut-out, using an experimentally validated porous foam material model. The mean concordance correlation coefficient between load to cut-out for the physical and simulated tests was 0.953 and 0.858 under static and dynamic loading, respectively. Under simulated dynamic loading, the volumes of yielding and failed bone foam were 15%, 32%, and 25% higher for Gamma3, PFNA-II, and TFNA than for DHS, suggesting that devices with similar forces at cut-out may produce relatively large differences in the volume of damaged bone tissue. Accurate simulation of material damage during dynamic loading may offer a useful alternative method for differentiating device performance in support of clinical decision-making around implant selection.

Journal of Orthopaedic Research®Vol. 44(2)
American Academy of Orthopaedic Surgeons (US), Hai Kang Life (China) (CN), University of Hong Kong (HK)
Openalex Percentile: Top 60%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.