Influence of Geometry, Class Imbalance and Alignment on Phantom Reconstruction Accuracy - A Micro-CT Phantom-Based Evaluation

The accuracy of the 3D models created from medical scans depends on every stage of the pipeline - segmentation, alignment, and surface extraction. Although segmentation algorithms are well established, the effects of the type of geometry, class imbalance and voxel and point cloud alignment on accuracy remain to be sufficiently explored. This work evaluates the reconstruction accuracy and also studies the effect of voxel alignment on overlap accuracy metrics using controlled perturbation analysis. A sphere, a facemask, and an abdominal aortic aneurysm (AAA) were printed using the stereolithography technique and scanned using a micro-CT machine. Segmentation was performed using Gaussian Mixture Model (GMM), Otsu thresholding and region-growing (RG) based methods. Segmented and reference models were aligned using the Kabsch-Umeyama (KU) algorithm to evaluate Dice and Jaccard scores, precision, among others. A sensitivity analysis quantified the effect of controlled translational (±5 voxels) and rotational (±5°) perturbations on post-KU-aligned voxel grids. Surface meshes, generated using the marching cubes algorithm, were registered with reference meshes using RANSAC and ICP alignment process. Otsu thresholding yielded highest accuracy for all the geometries. The sphere, with uniform curvature and no thin-walled regions, showed the lowest sensitivity to alignment error. AAA yielded low overlap scores due to its small wall thickness and sensitivity to misalignment. AAA model was most sensitive to misalignment, with Dice and Jaccard scores decreasing by more than 90% under 5° rotation and by over 60% due to just 1°. The facemask surface was most error-prone, possibly due to misalignment during the ICP process. The Jaccard index yields numerically lower values and larger relative changes under perturbations than the Dice score, making alignment sensitivity more apparent for thin-walled structures. Even a sub-millimetre error in voxel alignment adversely affects accuracy. Surface-based accuracy metrics differed from the voxel-based trends, and this divergence carries diagnostic value.

Authors

Institutions

Publication Details

Journal
Medical Engineering & Physics
Published
2026-11-02
DOI
https://doi.org/10.1088/1873-4030/aebc8e
Primary Topic
Medical Image Segmentation Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of Geometry, Class Imbalance and Alignment on Phantom Reconstruction Accuracy - A Micro-CT Phantom-Based Evaluation

Samarth S. Raut, Avinash Kumar K M
Medical Engineering & Physics
Medical Image Segmentation Techniques
article

Influence of Geometry, Class Imbalance and Alignment on Phantom Reconstruction Accuracy - A Micro-CT Phantom-Based Evaluation

Samarth S. Raut, Avinash Kumar K M
article en

Abstract

The accuracy of the 3D models created from medical scans depends on every stage of the pipeline - segmentation, alignment, and surface extraction. Although segmentation algorithms are well established, the effects of the type of geometry, class imbalance and voxel and point cloud alignment on accuracy remain to be sufficiently explored. This work evaluates the reconstruction accuracy and also studies the effect of voxel alignment on overlap accuracy metrics using controlled perturbation analysis. A sphere, a facemask, and an abdominal aortic aneurysm (AAA) were printed using the stereolithography technique and scanned using a micro-CT machine. Segmentation was performed using Gaussian Mixture Model (GMM), Otsu thresholding and region-growing (RG) based methods. Segmented and reference models were aligned using the Kabsch-Umeyama (KU) algorithm to evaluate Dice and Jaccard scores, precision, among others. A sensitivity analysis quantified the effect of controlled translational (±5 voxels) and rotational (±5°) perturbations on post-KU-aligned voxel grids. Surface meshes, generated using the marching cubes algorithm, were registered with reference meshes using RANSAC and ICP alignment process. Otsu thresholding yielded highest accuracy for all the geometries. The sphere, with uniform curvature and no thin-walled regions, showed the lowest sensitivity to alignment error. AAA yielded low overlap scores due to its small wall thickness and sensitivity to misalignment. AAA model was most sensitive to misalignment, with Dice and Jaccard scores decreasing by more than 90% under 5° rotation and by over 60% due to just 1°. The facemask surface was most error-prone, possibly due to misalignment during the ICP process. The Jaccard index yields numerically lower values and larger relative changes under perturbations than the Dice score, making alignment sensitivity more apparent for thin-walled structures. Even a sub-millimetre error in voxel alignment adversely affects accuracy. Surface-based accuracy metrics differed from the voxel-based trends, and this divergence carries diagnostic value.

Medical Engineering & Physics
Indian Institute of Technology Dharwad (IN)
Science and Engineering Research Board
Good health and well-being
Openalex Percentile: Top 93%
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon