Experimental investigation on human thermal responses to static and dynamic ramp temperatures in simulated hot-humid underground environments

• Thermal responses under static and dynamic temperatures were studied. • Subject experienced short-term heat acclimatization under static conditions. • Rising air temperature caused hysteresis effects in core temperature response. • Skin temperature threshold decreased by 0.82°C under dynamic conditions. Thermal conditions in underground environments are critical for occupants' safety, health, and productivity. While workers in these settings typically experience dynamic thermal variations, existing research has predominantly focused on static conditions. This study experimentally investigates human physiological and perceptual responses under both static (29, 32 °C) and dynamic ramp-change conditions (26–32/35/38 °C) in a climate chamber. The thermal sensation vote (TSV), thermal comfort vote (TCV), wetness sensation vote (WSV), core temperature (T c ), and mean skin temperature (T sk ) were assessed. Results indicate that under static conditions, these parameters stabilised after 20–30 min due to short-term thermal acclimatisation. Under dynamic conditions, they continued to evolve and exceeded static levels after approximately 40 min. As the ambient temperature increased from 26 to 38 °C, 7.39% of subjects experienced severe dyspnea, and heart rate and total fluid loss significantly increased by 10.51 bpm and 54.15 g compared with a static 32 °C condition. T sk , TSV, and WSV increased markedly, while TCV demonstrated a declining trend. A hysteresis phenomenon was observed, whereby the average core temperature under dynamic conditions was lower than that under static conditions, which diminished with larger temperature increases. A strong linear correlation was identified among TSV, TCV, T c, and T sk , indicating that the rate of T c acceleration increased when T sk exceeded 35.24°C. Notably, the core temperature threshold for mild discomfort (TCV>-0.5) under dynamic conditions is 37.19°C, which is 0.82°C lower than that under static conditions. The increase rate of T c accelerates significantly from 0.005°C/min to 0.012°C/min when T sk exceeds 35.24°C. Under 26–38°C condition, 7.39% of subjects experienced severe dyspnea, with heart rate and total fluid loss increasing by 10.51 bpm and 54.15 g compared to 32°C condition. These findings provide critical insights for improving workers' thermal comfort in hot-humid underground environments.

Authors

Institutions

Publication Details

Journal
Energy and Built Environment
Published
2026-02-01
DOI
https://doi.org/10.1016/j.enbenv.2026.02.005
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation on human thermal responses to static and dynamic ramp temperatures in simulated hot-humid underground environments

Yangjie Wang, Chenyu Wan, Xiaojuan Lai, Wenbo Fan et al.
Energy and Built Environment
Thermoregulation and physiological responses
article

Experimental investigation on human thermal responses to static and dynamic ramp temperatures in simulated hot-humid underground environments

Yangjie Wang, Chenyu Wan, Xiaojuan Lai, Wenbo Fan, Xingming Wang
article en

Abstract

• Thermal responses under static and dynamic temperatures were studied. • Subject experienced short-term heat acclimatization under static conditions. • Rising air temperature caused hysteresis effects in core temperature response. • Skin temperature threshold decreased by 0.82°C under dynamic conditions. Thermal conditions in underground environments are critical for occupants' safety, health, and productivity. While workers in these settings typically experience dynamic thermal variations, existing research has predominantly focused on static conditions. This study experimentally investigates human physiological and perceptual responses under both static (29, 32 °C) and dynamic ramp-change conditions (26–32/35/38 °C) in a climate chamber. The thermal sensation vote (TSV), thermal comfort vote (TCV), wetness sensation vote (WSV), core temperature (T c ), and mean skin temperature (T sk ) were assessed. Results indicate that under static conditions, these parameters stabilised after 20–30 min due to short-term thermal acclimatisation. Under dynamic conditions, they continued to evolve and exceeded static levels after approximately 40 min. As the ambient temperature increased from 26 to 38 °C, 7.39% of subjects experienced severe dyspnea, and heart rate and total fluid loss significantly increased by 10.51 bpm and 54.15 g compared with a static 32 °C condition. T sk , TSV, and WSV increased markedly, while TCV demonstrated a declining trend. A hysteresis phenomenon was observed, whereby the average core temperature under dynamic conditions was lower than that under static conditions, which diminished with larger temperature increases. A strong linear correlation was identified among TSV, TCV, T c, and T sk , indicating that the rate of T c acceleration increased when T sk exceeded 35.24°C. Notably, the core temperature threshold for mild discomfort (TCV>-0.5) under dynamic conditions is 37.19°C, which is 0.82°C lower than that under static conditions. The increase rate of T c accelerates significantly from 0.005°C/min to 0.012°C/min when T sk exceeds 35.24°C. Under 26–38°C condition, 7.39% of subjects experienced severe dyspnea, with heart rate and total fluid loss increasing by 10.51 bpm and 54.15 g compared to 32°C condition. These findings provide critical insights for improving workers' thermal comfort in hot-humid underground environments.

Energy and Built Environment
China University of Mining and Technology (CN), China Coal Technology and Engineering Group Corp (China) (CN)
Climate action
Openalex Percentile: Top 58%
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.