Synergistic electrocoagulation in a self-induced airlift reactor: A leap towards energy-efficient and sustainable tannery wastewater remediation

Tannery wastewater is a challenging effluent due to its high concentrations of chromium, total sulfides, and recalcitrant organic compounds. This study presented a novel electrocoagulation (EC) process using a self-induced external-loop airlift reactor (ELAR), which operated without mechanical mixing and relied on hydrogen and oxygen microbubbles for internal circulation. Under optimal conditions (pH of 6, a current density of 50 mA/cm 2 , an electrolysis time of 20 min), the ELAR achieved high pollutant removal efficiencies (88% chemical oxygen demand (COD) removal and 92% Cr removal) with lower energy consumption (10.8 kW·h/m 3 ) and reduced operational costs (1.83 USD per cubic meter) compared to a stirred tank reactor. Artificial neural network (ANN) modeling enabled data-driven optimization, further improving COD removal to 94% with reducing energy input. Kinetic and isotherm analyses confirmed chemisorption as the dominant mechanism. Life cycle assessment (LCA) and solar integration scenarios highlighted the environmental benefits of the ELAR system. Sludge characterization indicated potential for reuse as construction materials. This study uniquely introduced an ELAR system that operated without mechanical agitation, combined with ANN modeling and LCA, representing the first integrated approach for optimizing and assessing EC performance in tannery wastewater treatment. These findings demonstrate that the ELAR EC system offers a cost-effective and sustainable solution for industrial wastewater remediation.

Authors

Institutions

Publication Details

Journal
Water Science and Engineering
Published
2026-02-01
DOI
https://doi.org/10.1016/j.wse.2026.02.002
Primary Topic
Advanced oxidation water treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synergistic electrocoagulation in a self-induced airlift reactor: A leap towards energy-efficient and sustainable tannery wastewater remediation

Reda Elkacmi, Rajaa Zahnoune, Redouane Elamri, Maryeme Hamdouch et al.
Water Science and Engineering
Advanced oxidation water treatment
article

Synergistic electrocoagulation in a self-induced airlift reactor: A leap towards energy-efficient and sustainable tannery wastewater remediation

Reda Elkacmi, Rajaa Zahnoune, Redouane Elamri, Maryeme Hamdouch, Otmane Boudouch, Abdelfattah El mahbouby
article en

Abstract

Tannery wastewater is a challenging effluent due to its high concentrations of chromium, total sulfides, and recalcitrant organic compounds. This study presented a novel electrocoagulation (EC) process using a self-induced external-loop airlift reactor (ELAR), which operated without mechanical mixing and relied on hydrogen and oxygen microbubbles for internal circulation. Under optimal conditions (pH of 6, a current density of 50 mA/cm 2 , an electrolysis time of 20 min), the ELAR achieved high pollutant removal efficiencies (88% chemical oxygen demand (COD) removal and 92% Cr removal) with lower energy consumption (10.8 kW·h/m 3 ) and reduced operational costs (1.83 USD per cubic meter) compared to a stirred tank reactor. Artificial neural network (ANN) modeling enabled data-driven optimization, further improving COD removal to 94% with reducing energy input. Kinetic and isotherm analyses confirmed chemisorption as the dominant mechanism. Life cycle assessment (LCA) and solar integration scenarios highlighted the environmental benefits of the ELAR system. Sludge characterization indicated potential for reuse as construction materials. This study uniquely introduced an ELAR system that operated without mechanical agitation, combined with ANN modeling and LCA, representing the first integrated approach for optimizing and assessing EC performance in tannery wastewater treatment. These findings demonstrate that the ELAR EC system offers a cost-effective and sustainable solution for industrial wastewater remediation.

Water Science and Engineering
Université Sultan Moulay Slimane (MA), Chouaib Doukkali University (MA), University of Hassan II Casablanca (MA)
Responsible consumption and production
Openalex Percentile: Top 63%
Advanced oxidation water treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Synergistic electrocoagulation in a self-induced airlift reactor: A leap towards energy-efficient and sustainable tannery wastewater remediation — Reda Elkacmi, Rajaa Zahnoune, et al. · Water Science and Engineering (2026) | TGRS Research Map | TGRS