Ru(bpy) <sub>3</sub> <sup>2+</sup> ‐DBAE Coreactant‐SDS Enhancer Systems on Automated Electrochemiluminescence Immunoassay Analyzer Containing Pt Electrode for Highly Sensitive Detection of Carbohydrate Antigen 19‐9

This work reports one Ru(bpy)<sub>3</sub> <sup>2+</sup>-N,N-dibutylethanolamine (DBAE) coreactant-sodium dodecyl sulfate (SDS) enhancer system on an automated electrochemiluminescence immunoassay (ECLIA) analyzer for the ECL immunoassay of carbohydrate antigen 19-9 (CA19-9). The ECL intensity of the MB@SA•biotin-GSK-Ru1 bio-conjugates in DBAE solution on the automated ECLIA analyzer, which employs a platinum working electrode under the "Heterogeneous" model, demonstrates a 333% enhancement in comparison with that of the conventional tri-n-propylamine coreactant. Subsequently, the developed novel DBAE coreactant-based automated ECL method was estimated by the determination of CA19-9, while the MB@SA•biotin-Ab1 was taken as the capture probe and the Ru(bpy)<sub>3</sub> <sup>2+</sup> derivative-labeled CA19-9 antibody (Ab2-Ru1) was employed as signal probe. In the presence of the SDS enhancer, the relative ECL intensity of the formed "sandwich" MB@SA•biotin-Ab1/CA19-9/Ab2-Ru1 biocomplexes exhibits a 4.3-fold enhancement on the automated ECLIA analyzer. Notably, under the optimized conditions, the increased ECL intensity was directly in proportion to the concentration of CA19-9 in the range from 0.5 to 8.0 U/mL with a limit of detection of 0.25 U/mL. This approach has the potential to be extended to magnetic bead-based automated ECL methods for the sensitive detection of clinical protein biomarkers.

Authors

Institutions

Publication Details

Journal
Chemistry - An Asian Journal
Published
2026-02-01
DOI
https://doi.org/10.1002/asia.202500998
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ru(bpy) 3 2+ ‐DBAE Coreactant‐SDS Enhancer Systems on Automated Electrochemiluminescence Immunoassay Analyzer Containing Pt Electrode for Highly Sensitive Detection of Carbohydrate Antigen 19‐9

Zimei Wang, Xiaolin yang, Yuxi Wei, Honglan Qi et al.
Chemistry - An Asian Journal
Advanced biosensing and bioanalysis techniques
article

Ru(bpy) 3 2+ ‐DBAE Coreactant‐SDS Enhancer Systems on Automated Electrochemiluminescence Immunoassay Analyzer Containing Pt Electrode for Highly Sensitive Detection of Carbohydrate Antigen 19‐9

Zimei Wang, Xiaolin yang, Yuxi Wei, Honglan Qi, Chengkai Wang, Chengxiao Zhang, Yaping Ma
article en

Abstract

This work reports one Ru(bpy)<sub>3</sub> <sup>2+</sup>-N,N-dibutylethanolamine (DBAE) coreactant-sodium dodecyl sulfate (SDS) enhancer system on an automated electrochemiluminescence immunoassay (ECLIA) analyzer for the ECL immunoassay of carbohydrate antigen 19-9 (CA19-9). The ECL intensity of the MB@SA•biotin-GSK-Ru1 bio-conjugates in DBAE solution on the automated ECLIA analyzer, which employs a platinum working electrode under the "Heterogeneous" model, demonstrates a 333% enhancement in comparison with that of the conventional tri-n-propylamine coreactant. Subsequently, the developed novel DBAE coreactant-based automated ECL method was estimated by the determination of CA19-9, while the MB@SA•biotin-Ab1 was taken as the capture probe and the Ru(bpy)<sub>3</sub> <sup>2+</sup> derivative-labeled CA19-9 antibody (Ab2-Ru1) was employed as signal probe. In the presence of the SDS enhancer, the relative ECL intensity of the formed "sandwich" MB@SA•biotin-Ab1/CA19-9/Ab2-Ru1 biocomplexes exhibits a 4.3-fold enhancement on the automated ECLIA analyzer. Notably, under the optimized conditions, the increased ECL intensity was directly in proportion to the concentration of CA19-9 in the range from 0.5 to 8.0 U/mL with a limit of detection of 0.25 U/mL. This approach has the potential to be extended to magnetic bead-based automated ECL methods for the sensitive detection of clinical protein biomarkers.

Chemistry - An Asian JournalVol. 21(3)
First Hospital of Xi'an (CN), Shaanxi Normal University (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 61%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.