The effectiveness of the diazoxide test in the determination of tip-end position after blind Insertion of the nasoenteric tube by ICU nurses: A prospective comparative study

This study aimed to investigate the predictive value of the diazoxide test for determining the tip position of blindly inserted nasoenteric tubes in ICU bedridden patients, and to compare its diagnostic accuracy with other common bedside methods. This prospective comparative study was conducted in the ICU of a tertiary hospital, and a consecutive sample of 436 patients requiring blind nasoenteric tube insertion was enrolled from June 2021 to January 2022. The tip position was pre-determined using the diazoxide test, the auscultation of water sound, the guidewire rebound test, the negative pressure test, judging the nature of the digestive fluid, and the pH test. The final confirmation was obtained through X-ray analysis. Diagnostic parameters, including accuracy, sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios, Youden’s index, the Kappa coefficient, and the area under the receiver operating characteristic (ROC) curve (AUC), were calculated and compared. A total of 427 patients completed the diagnostic methods described above. The diazoxide test demonstrated the highest accuracy and Kappa coefficient, with values of 92.3% and 0.767, respectively. It also exhibited the most significant AUC of 0.879 (confidence interval: 0.829-0.929) and the highest Youden’s index of 0.757. The pH test determination method achieved the highest sensitivity and negative result rates, at 97.3% and 83.0%, respectively. The process for assessing the nature of digestive fluid yielded the highest values for specificity, positive predictive value, and favorable likelihood ratio, at 83.5%, 94.9%, and 5.030, respectively. The diazoxide test, as a predictive method, can effectively determine the success of nasoenteric tube placement and reduce patient pain.

Authors

Institutions

Publication Details

Journal
International Journal of Nursing Sciences
Published
2026-02-01
DOI
https://doi.org/10.1016/j.ijnss.2026.02.007
Primary Topic
Nosocomial Infections in ICU
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The effectiveness of the diazoxide test in the determination of tip-end position after blind Insertion of the nasoenteric tube by ICU nurses: A prospective comparative study

Xiaoyun Wang, Yan Li, Xiuling Zhong, Li Li et al.
International Journal of Nursing Sciences
Nosocomial Infections in ICU
article

The effectiveness of the diazoxide test in the determination of tip-end position after blind Insertion of the nasoenteric tube by ICU nurses: A prospective comparative study

Xiaoyun Wang, Yan Li, Xiuling Zhong, Li Li, Chun Song, Qing Liu, Kun Wen, Lu Zhang
article en

Abstract

This study aimed to investigate the predictive value of the diazoxide test for determining the tip position of blindly inserted nasoenteric tubes in ICU bedridden patients, and to compare its diagnostic accuracy with other common bedside methods. This prospective comparative study was conducted in the ICU of a tertiary hospital, and a consecutive sample of 436 patients requiring blind nasoenteric tube insertion was enrolled from June 2021 to January 2022. The tip position was pre-determined using the diazoxide test, the auscultation of water sound, the guidewire rebound test, the negative pressure test, judging the nature of the digestive fluid, and the pH test. The final confirmation was obtained through X-ray analysis. Diagnostic parameters, including accuracy, sensitivity, specificity, positive and negative predictive values, positive and negative likelihood ratios, Youden’s index, the Kappa coefficient, and the area under the receiver operating characteristic (ROC) curve (AUC), were calculated and compared. A total of 427 patients completed the diagnostic methods described above. The diazoxide test demonstrated the highest accuracy and Kappa coefficient, with values of 92.3% and 0.767, respectively. It also exhibited the most significant AUC of 0.879 (confidence interval: 0.829-0.929) and the highest Youden’s index of 0.757. The pH test determination method achieved the highest sensitivity and negative result rates, at 97.3% and 83.0%, respectively. The process for assessing the nature of digestive fluid yielded the highest values for specificity, positive predictive value, and favorable likelihood ratio, at 83.5%, 94.9%, and 5.030, respectively. The diazoxide test, as a predictive method, can effectively determine the success of nasoenteric tube placement and reduce patient pain.

International Journal of Nursing Sciences
Shandong University (CN), University of Jinan (CN), Shandong Management University (CN), Second Hospital of Shandong University (CN), Qilu Hospital of Shandong University (CN)
Clean water and sanitation
Openalex Percentile: Top 61%
Nosocomial Infections in ICU
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.