Effects of hydrothermal treatment time on the release kinetics of Ni <sup>2+</sup> and Zn <sup>2+</sup> , corrosion behavior and biological properties of Zn-supported Ni-Ti-O nanopores coatings

Bone implant materials with excellent corrosion resistance, antibacterial property, and controlled ion release kinetics are crucial for their clinical application. In this study, Zn-supported Ni-Ti-O nanopores (NPs) coating was prepared on the surface of nickel-titanium (NiTi) implants by anodization and hydrothermal treatment (HT), the effects of HT time on coatings structure, antibacterial property, corrosion resistance, Ni<sup>2+</sup> and Zn<sup>2+</sup> release behavior and biocompatibility were studied. The results indicate that with the extension of HT time, the coating thickness increases, while the diameters of the NPs decrease. After 3 h of HT, the average diameter of the NPs is 42.52 nm, which is about 1/2 of that after anodization (86.63 nm). Furthermore, our experimental results show that with the extension of HT time, the corrosion resistance is improved, and the corrosion current density of the sample NP-30-Zn-3h is 3.214 × 10<sup>-8</sup> A⋅cm<sup>-2</sup>, which is one order of magnitude lower than that of the NiTi substrate (7.529 × 10<sup>-7</sup> A⋅cm<sup>-2</sup>). In addition, Zn-supported Ni-Ti-O NPs coatings exhibit excellent antibacterial property and biocompatibility, especially the sample NP-30-Zn-3h. Interestingly, with the extension of HT time, the release of Ni<sup>2+</sup> and Zn<sup>2+</sup> is inhibited, and Zn<sup>2+</sup> concentration released from the sample NP-30-Zn-3h is about 3.65 mg/L at days 7 and 14, which is close to the reported osteoblast-stimulating concentration of 3.53 mg/L.

Authors

Institutions

Publication Details

Journal
Journal of Biomaterials Applications
Published
2026-02-10
DOI
https://doi.org/10.1177/08853282261424660
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of hydrothermal treatment time on the release kinetics of Ni 2+ and Zn 2+ , corrosion behavior and biological properties of Zn-supported Ni-Ti-O nanopores coatings

Zhijian Li, Yuehua Huang, Zhiyan Lv, Hailing Lao
Journal of Biomaterials Applications
Bone Tissue Engineering Materials
article

Effects of hydrothermal treatment time on the release kinetics of Ni 2+ and Zn 2+ , corrosion behavior and biological properties of Zn-supported Ni-Ti-O nanopores coatings

Zhijian Li, Yuehua Huang, Zhiyan Lv, Hailing Lao
article en

Abstract

Bone implant materials with excellent corrosion resistance, antibacterial property, and controlled ion release kinetics are crucial for their clinical application. In this study, Zn-supported Ni-Ti-O nanopores (NPs) coating was prepared on the surface of nickel-titanium (NiTi) implants by anodization and hydrothermal treatment (HT), the effects of HT time on coatings structure, antibacterial property, corrosion resistance, Ni<sup>2+</sup> and Zn<sup>2+</sup> release behavior and biocompatibility were studied. The results indicate that with the extension of HT time, the coating thickness increases, while the diameters of the NPs decrease. After 3 h of HT, the average diameter of the NPs is 42.52 nm, which is about 1/2 of that after anodization (86.63 nm). Furthermore, our experimental results show that with the extension of HT time, the corrosion resistance is improved, and the corrosion current density of the sample NP-30-Zn-3h is 3.214 × 10<sup>-8</sup> A⋅cm<sup>-2</sup>, which is one order of magnitude lower than that of the NiTi substrate (7.529 × 10<sup>-7</sup> A⋅cm<sup>-2</sup>). In addition, Zn-supported Ni-Ti-O NPs coatings exhibit excellent antibacterial property and biocompatibility, especially the sample NP-30-Zn-3h. Interestingly, with the extension of HT time, the release of Ni<sup>2+</sup> and Zn<sup>2+</sup> is inhibited, and Zn<sup>2+</sup> concentration released from the sample NP-30-Zn-3h is about 3.65 mg/L at days 7 and 14, which is close to the reported osteoblast-stimulating concentration of 3.53 mg/L.

Journal of Biomaterials Applications
Beijing Health Vocational College (CN), Shanxi University of Traditional Chinese Medicine (CN)
Clean water and sanitation
Openalex Percentile: Top 61%
Bone Tissue Engineering Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.