Analysis and Adaptive Separation of IGBT Switching Noise in PD Monitoring of Flexible HVDC Valves: An Evolutionary Perspective

The high-frequency switching noise of insulated-gate bipolar transistors (IGBTs) limits the sensitivity of online partial discharge (PD) monitoring in ultra-high-voltage flexible DC (VSC-HVDC) transmission systems. To address this challenge, this study investigates the underlying mechanisms and evolution of this interference and develops an anti-interference signal separation method. Simulation and experimental results indicate that the energy of IGBT switching noise is concentrated in the 30–180 MHz range, which significantly overlaps with the ultra-high-frequency (UHF) band used for PD detection. This research further reveals the pronounced modulation effect of device aging on the interference spectrum: bond wire aging triggers “spectral reconstruction” via altered parasitic parameters, where severe collector aging leads to an abnormal surge in turn-off interference amplitude. In contrast, gate oxide layer degradation manifests as characteristic “global spectrum attenuation” and a shift in peak frequency toward lower bands. Confronted with the challenges of strong interference and spectrum drift induced by aging, this paper proposes an adaptive signal separation method based on feature optimization of the time–frequency cumulative energy function. This method constructs novel characteristic parameters—namely, oblique intercept width and morphological gradient steepness—to effectively capture the fundamental differences in the energy accumulation process of the signals. Experimental verification demonstrates that even under conditions of varying interference characteristics, the proposed method achieves high-precision separation of PD signals from IGBT noise, outperforming traditional equivalent time–frequency and wavelet principal component analysis methods. This research provides crucial theoretical and technical support for insulation condition monitoring and device aging diagnosis in VSC-HVDC converter valves.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-02-10
DOI
https://doi.org/10.3390/electronics15040751
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Adaptive Separation of IGBT Switching Noise in PD Monitoring of Flexible HVDC Valves: An Evolutionary Perspective

Qifeng Bian, Huanmin Yao, Tong Bai, Maoqun Shen et al.
Electronics
High voltage insulation and dielectric phenomena
article

Analysis and Adaptive Separation of IGBT Switching Noise in PD Monitoring of Flexible HVDC Valves: An Evolutionary Perspective

Qifeng Bian, Huanmin Yao, Tong Bai, Maoqun Shen, GuangSheng Cai, Jiangfeng Si, Haibao Mu, Bing Yu, Yongtao Jin
article en

Abstract

The high-frequency switching noise of insulated-gate bipolar transistors (IGBTs) limits the sensitivity of online partial discharge (PD) monitoring in ultra-high-voltage flexible DC (VSC-HVDC) transmission systems. To address this challenge, this study investigates the underlying mechanisms and evolution of this interference and develops an anti-interference signal separation method. Simulation and experimental results indicate that the energy of IGBT switching noise is concentrated in the 30–180 MHz range, which significantly overlaps with the ultra-high-frequency (UHF) band used for PD detection. This research further reveals the pronounced modulation effect of device aging on the interference spectrum: bond wire aging triggers “spectral reconstruction” via altered parasitic parameters, where severe collector aging leads to an abnormal surge in turn-off interference amplitude. In contrast, gate oxide layer degradation manifests as characteristic “global spectrum attenuation” and a shift in peak frequency toward lower bands. Confronted with the challenges of strong interference and spectrum drift induced by aging, this paper proposes an adaptive signal separation method based on feature optimization of the time–frequency cumulative energy function. This method constructs novel characteristic parameters—namely, oblique intercept width and morphological gradient steepness—to effectively capture the fundamental differences in the energy accumulation process of the signals. Experimental verification demonstrates that even under conditions of varying interference characteristics, the proposed method achieves high-precision separation of PD signals from IGBT noise, outperforming traditional equivalent time–frequency and wavelet principal component analysis methods. This research provides crucial theoretical and technical support for insulation condition monitoring and device aging diagnosis in VSC-HVDC converter valves.

ElectronicsVol. 15(4)
Electric Power Research Institute (US), State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN), Xi'an Jiaotong University (CN)
Science and Technology Project of State Grid
Affordable and clean energy
Openalex Percentile: Top 62%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.