Is synovial calprotectin lateral flow test a reliable intraoperative biomarker for periprosthetic joint infection? A systematic review and meta-analysis

Periprosthetic Joint Infection (PJI) remains one of the most challenging complications in arthroplasty, often leading to diagnostic uncertainty and suboptimal treatment decisions. Synovial calprotectin has emerged as a promising biomarker, with the lateral flow test (LFT) offering real-time results for intraoperative decision-making. This meta-analysis aimed to evaluate the diagnostic accuracy of intraoperative synovial calprotectin LFT in detecting PJI. A systematic review and meta-analysis were conducted according to PRISMA guidelines. Thirteen studies comprising 990 patients were included. Pooled sensitivity, specificity, positive and negative predictive values (PPV, NPV), likelihood ratios (LR+, LR−), diagnostic odds ratio (DOR), and area under the curve (AUC) were calculated using a random-effects model. Subgroup analyses were performed based on test kit type and calprotectin cutoff values. The pooled sensitivity and specificity of synovial calprotectin LFT were 88% (95% CI: 82–92%) and 89% (95% CI: 83–93%), respectively, with an AUC of 0.94. The DOR was 56.1 (95% CI: 28.4-110.8). The ≥ 50 mg/L cutoff subgroup demonstrated superior diagnostic performance across all metrics. Despite subgroup analysis, heterogeneity remained high (I² = 74.1%), likely due to differences in reference standards, joint types, and study design. Intraoperative synovial calprotectin LFT is a highly accurate and rapid diagnostic tool for PJI, with strong applicability in real-world surgical settings. Its cost-effectiveness and ease of use support its integration as a valuable adjunctive marker within standard diagnostic algorithms, providing supplementary evidence when conventional criteria remain inconclusive.

Authors

Institutions

Publication Details

Journal
Archives of Orthopaedic and Trauma Surgery
Published
2026-02-10
DOI
https://doi.org/10.1007/s00402-026-06202-w
Primary Topic
Orthopedic Infections and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Is synovial calprotectin lateral flow test a reliable intraoperative biomarker for periprosthetic joint infection? A systematic review and meta-analysis

Athanasios Ververidis, Konstantinos Giatroudakis, Efthymios Iliopoulos, Konstantinos Kateros
Archives of Orthopaedic and Trauma Surgery
Orthopedic Infections and Treatments
article

Is synovial calprotectin lateral flow test a reliable intraoperative biomarker for periprosthetic joint infection? A systematic review and meta-analysis

Athanasios Ververidis, Konstantinos Giatroudakis, Efthymios Iliopoulos, Konstantinos Kateros
article en

Abstract

Periprosthetic Joint Infection (PJI) remains one of the most challenging complications in arthroplasty, often leading to diagnostic uncertainty and suboptimal treatment decisions. Synovial calprotectin has emerged as a promising biomarker, with the lateral flow test (LFT) offering real-time results for intraoperative decision-making. This meta-analysis aimed to evaluate the diagnostic accuracy of intraoperative synovial calprotectin LFT in detecting PJI. A systematic review and meta-analysis were conducted according to PRISMA guidelines. Thirteen studies comprising 990 patients were included. Pooled sensitivity, specificity, positive and negative predictive values (PPV, NPV), likelihood ratios (LR+, LR−), diagnostic odds ratio (DOR), and area under the curve (AUC) were calculated using a random-effects model. Subgroup analyses were performed based on test kit type and calprotectin cutoff values. The pooled sensitivity and specificity of synovial calprotectin LFT were 88% (95% CI: 82–92%) and 89% (95% CI: 83–93%), respectively, with an AUC of 0.94. The DOR was 56.1 (95% CI: 28.4-110.8). The ≥ 50 mg/L cutoff subgroup demonstrated superior diagnostic performance across all metrics. Despite subgroup analysis, heterogeneity remained high (I² = 74.1%), likely due to differences in reference standards, joint types, and study design. Intraoperative synovial calprotectin LFT is a highly accurate and rapid diagnostic tool for PJI, with strong applicability in real-world surgical settings. Its cost-effectiveness and ease of use support its integration as a valuable adjunctive marker within standard diagnostic algorithms, providing supplementary evidence when conventional criteria remain inconclusive.

Archives of Orthopaedic and Trauma SurgeryVol. 146(1)
Democritus University of Thrace (GR), General Hospital of Athens G. Genimatas (GR), University Hospital of Alexandroupolis (GR)
Peace, Justice and strong institutions
Openalex Percentile: Top 61%
Orthopedic Infections and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.