Pan centromeric FISH enhances precision in radiation biodosimetry

Accurate biodosimetry is critical for assessing radiation exposure in radiological emergencies, occupational monitoring, and clinical management, where precise dose estimation informs life-saving decisions and regulatory compliance. Current gold-standard cytogenetic methods face limitations in sensitivity and reproducibility, especially at low doses (< 0.5 Gy) (practical limitations at low doses, including very low dicentric yields, higher statistical noise, and greater scoring uncertainty as aberration frequencies near background levels). This study presents a systematic comparison of pan-centromeric fluorescence in situ hybridization (pan-cent-FISH) and Giemsa staining for detecting dicentric (DC) and ring (R) chromosomes following 60Co-γ irradiation (0–3 Gy). Analysis of more than 15,000 metaphases per technique revealed enhanced sensitivity of pan-cent-FISH technique, demonstrating a 1.72-fold higher linear coefficient and enhanced (1.13-fold) quadratic coefficient (β), indicating improved sensitivity across both low and high dose ranges. Blind validation with eight samples showed pan-cent-FISH achieved ~ 2-fold greater accuracy, with mean absolute differences of 0.0538 Gy (vs. 0.1105 Gy for Giemsa) and average relative errors of 7.13% (vs. 15.35% for Giemsa). At low doses (0.1 Gy), pan-cent-FISH maintained 9.0% error, while Giemsa exceeded acceptable limits (21.0% error). The standardized fluorescence detection used for the technique eliminated morphological ambiguities, reducing false negatives by ~ 40% and improving first-pass accuracy.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-10
DOI
https://doi.org/10.1038/s41598-025-34407-3
Primary Topic
Carcinogens and Genotoxicity Assessment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pan centromeric FISH enhances precision in radiation biodosimetry

Balvinder Kaur Sapra, Nagesh Bhat, Rajesh Kumar Chaurasia, Kapil B. Shirsath et al.
Scientific Reports
Carcinogens and Genotoxicity Assessment
article

Pan centromeric FISH enhances precision in radiation biodosimetry

Balvinder Kaur Sapra, Nagesh Bhat, Rajesh Kumar Chaurasia, Kapil B. Shirsath, Aarti Notnani, Devina Fenilon Vaz, Arshad Khan, Sheeri Fatima, Dhruv Kumar
article en

Abstract

Accurate biodosimetry is critical for assessing radiation exposure in radiological emergencies, occupational monitoring, and clinical management, where precise dose estimation informs life-saving decisions and regulatory compliance. Current gold-standard cytogenetic methods face limitations in sensitivity and reproducibility, especially at low doses (< 0.5 Gy) (practical limitations at low doses, including very low dicentric yields, higher statistical noise, and greater scoring uncertainty as aberration frequencies near background levels). This study presents a systematic comparison of pan-centromeric fluorescence in situ hybridization (pan-cent-FISH) and Giemsa staining for detecting dicentric (DC) and ring (R) chromosomes following 60Co-γ irradiation (0–3 Gy). Analysis of more than 15,000 metaphases per technique revealed enhanced sensitivity of pan-cent-FISH technique, demonstrating a 1.72-fold higher linear coefficient and enhanced (1.13-fold) quadratic coefficient (β), indicating improved sensitivity across both low and high dose ranges. Blind validation with eight samples showed pan-cent-FISH achieved ~ 2-fold greater accuracy, with mean absolute differences of 0.0538 Gy (vs. 0.1105 Gy for Giemsa) and average relative errors of 7.13% (vs. 15.35% for Giemsa). At low doses (0.1 Gy), pan-cent-FISH maintained 9.0% error, while Giemsa exceeded acceptable limits (21.0% error). The standardized fluorescence detection used for the technique eliminated morphological ambiguities, reducing false negatives by ~ 40% and improving first-pass accuracy.

Scientific ReportsVol. 16(1)
Bhabha Atomic Research Centre (IN), Homi Bhabha National Institute (IN), Bhabha Atomic Research Center Hospital (IN), University of Petroleum and Energy Studies (IN)
Bhabha Atomic Research Centre
Responsible consumption and production
Openalex Percentile: Top 63%
Carcinogens and Genotoxicity Assessment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.