Corrosion Control in Drinking Water Distribution Using Simple Methods

To investigate the effects of a corrosion inhibitor settling over an extended period, a two-part low-alloy steel pipe was taken from the drinking water network and installed in a test system. After an equilibration phase with inhibited water, the connected pipe sections were operated with inhibitor-free water for 600 days. During this time, stagnation tests were conducted to measure the increase in turbidity, oxygen consumption, and iron release. Corrosion rates and iron release rates were calculated from these parameters. Comparing the values at the beginning and end of the tests showed that the test pipe without the phosphate inhibitor did not exhibit a significant increase in the corrosion or iron release rate. The turbidity rates indicate that the legal limit for drinking water is reached after six hours of stagnation in the tested water. Under stable conditions, turbidity increased linearly over time, while oxygen consumption decreased linearly. Flushing significantly disturbed the corrosion system and increased the turbidity rate. The results obtained can be used to assess the risks associated with changes in water properties, in this study by discontinuing the addition of corrosion inhibitors, but also with modifications to water treatment such as aeration, softening, and desalination. In these cases, the impact on corrosive materials should be investigated beforehand. The results allow for the derivation of recommendations for optimizing the corrosion properties of the water or for implementing countermeasures in the supply network. The test procedure requires minimal personnel and financial resources, yet provides valuable insights into corrosion processes in the water-metal system.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-02-10
DOI
https://doi.org/10.5281/zenodo.18599289
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion Control in Drinking Water Distribution Using Simple Methods

P. Janknecht, Norbert Konradt, Monika Konradt
Zenodo (CERN European Organization for Nuclear Research)
Corrosion Behavior and Inhibition
article

Corrosion Control in Drinking Water Distribution Using Simple Methods

P. Janknecht, Norbert Konradt, Monika Konradt
article en

Abstract

To investigate the effects of a corrosion inhibitor settling over an extended period, a two-part low-alloy steel pipe was taken from the drinking water network and installed in a test system. After an equilibration phase with inhibited water, the connected pipe sections were operated with inhibitor-free water for 600 days. During this time, stagnation tests were conducted to measure the increase in turbidity, oxygen consumption, and iron release. Corrosion rates and iron release rates were calculated from these parameters. Comparing the values at the beginning and end of the tests showed that the test pipe without the phosphate inhibitor did not exhibit a significant increase in the corrosion or iron release rate. The turbidity rates indicate that the legal limit for drinking water is reached after six hours of stagnation in the tested water. Under stable conditions, turbidity increased linearly over time, while oxygen consumption decreased linearly. Flushing significantly disturbed the corrosion system and increased the turbidity rate. The results obtained can be used to assess the risks associated with changes in water properties, in this study by discontinuing the addition of corrosion inhibitors, but also with modifications to water treatment such as aeration, softening, and desalination. In these cases, the impact on corrosive materials should be investigated beforehand. The results allow for the derivation of recommendations for optimizing the corrosion properties of the water or for implementing countermeasures in the supply network. The test procedure requires minimal personnel and financial resources, yet provides valuable insights into corrosion processes in the water-metal system.

Zenodo (CERN European Organization for Nuclear Research)
Clean water and sanitation
Openalex Percentile: Top 62%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.