An improved rapid performance analysis model for solenoidal magnetic radiation shields

• An improved mass and dose estimation model for solenoidal magnetic radiation shields is presented and validated against a Monte Carlo simulation. • The model is used to rapidly evaluate the trade space of shield designs across key design variables. • Mass-optimal designs for a range of dose targets are identified and shown to greatly outperform passive shields in some cases. Astronauts participating in deep-space exploration missions will be exposed to significantly greater amounts of radiation than is typically encountered on Earth or in low Earth orbit (LEO), which poses significant risks to crew health and mission safety. Active magnetic radiation shields based on the Lorentz deflection of charged particles have the potential to reduce astronaut doses with lower mass costs than passive shielding techniques. Typically, active shielding performance is evaluated using high-fidelity Monte Carlo simulations, which are too computationally expensive to evaluate an entire trade space of shield designs. A rapid, semi-analytical model based on the High Charge and Energy Transport code (HZETRN) developed in 2015 provided an alternative method by which to evaluate the performance of solenoidal shields. However, various simplifying assumptions made in the original model have limited its accuracy, and therefore require evaluation and correction. In this work, a number of aspects of the original semi-analytical model are updated and validated by Monte Carlo simulation, then used to recharacterize the design trade space of solenoidal magnetic shields. The updated model predicts improved performance for weaker shields as compared to the original model, but greatly diminished performance for strong shields with bending powers greater than 20 T-m. Overall, the results indicate that magnetic shields enable significant mass savings over passive shields for mission scenarios where the requisite dose reduction is greater than about 60% relative to free space, which includes most exploration missions longer than one year with significant time spent outside LEO.

Authors

Institutions

Publication Details

Journal
Advances in Space Research
Published
2026-02-10
DOI
https://doi.org/10.1016/j.asr.2026.02.013
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An improved rapid performance analysis model for solenoidal magnetic radiation shields

Joseph L. Hesse-Withbroe, Katya Arquilla
Advances in Space Research
Radiation Therapy and Dosimetry
article

An improved rapid performance analysis model for solenoidal magnetic radiation shields

Joseph L. Hesse-Withbroe, Katya Arquilla
article en

Abstract

• An improved mass and dose estimation model for solenoidal magnetic radiation shields is presented and validated against a Monte Carlo simulation. • The model is used to rapidly evaluate the trade space of shield designs across key design variables. • Mass-optimal designs for a range of dose targets are identified and shown to greatly outperform passive shields in some cases. Astronauts participating in deep-space exploration missions will be exposed to significantly greater amounts of radiation than is typically encountered on Earth or in low Earth orbit (LEO), which poses significant risks to crew health and mission safety. Active magnetic radiation shields based on the Lorentz deflection of charged particles have the potential to reduce astronaut doses with lower mass costs than passive shielding techniques. Typically, active shielding performance is evaluated using high-fidelity Monte Carlo simulations, which are too computationally expensive to evaluate an entire trade space of shield designs. A rapid, semi-analytical model based on the High Charge and Energy Transport code (HZETRN) developed in 2015 provided an alternative method by which to evaluate the performance of solenoidal shields. However, various simplifying assumptions made in the original model have limited its accuracy, and therefore require evaluation and correction. In this work, a number of aspects of the original semi-analytical model are updated and validated by Monte Carlo simulation, then used to recharacterize the design trade space of solenoidal magnetic shields. The updated model predicts improved performance for weaker shields as compared to the original model, but greatly diminished performance for strong shields with bending powers greater than 20 T-m. Overall, the results indicate that magnetic shields enable significant mass savings over passive shields for mission scenarios where the requisite dose reduction is greater than about 60% relative to free space, which includes most exploration missions longer than one year with significant time spent outside LEO.

Advances in Space ResearchVol. 77(7)
University of Colorado Boulder (US)
Affordable and clean energy
Openalex Percentile: Top 63%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.