Silicone-Foam Passive Air Samplers for Combined Target and Nontarget Chemical Profiling and Toxicity Assessment of Airborne Exposomes

Polluted air is a major global health risk factor, yet the chemical composition and toxicity of airborne gases and particles remain underexplored due to their complexity and difficulties in sampling. We recently introduced how polydimethylsiloxane (PDMS) foam─or silicone foam─can be synthesized for passive air sampling, enabling simple and cost-effective nontarget chemical profiling of indoor air. Here, we demonstrate expanded applications, indoors and outdoors, with commercial PDMS-foam, including for: (i) wide-scope target analysis of >220 priority substances by quantitative liquid- and gas chromatography-high-resolution mass spectrometry, (ii) microscopic characterization and nontarget profiling of accumulated fine particles, and (iii) effect-guided discovery of harmful substances, combining toxicological data with nontarget analysis in silico. Median method quantification limits were 0.12 ng/mL, 90% of target analytes had absolute recoveries between 70 and 130%, and hazardous substances were discovered, including ethylene glycols, insecticides, and UV filters. Microscopy revealed the accumulation of abundant fine particles, and the automated characterization of the fluorescent fraction revealed that most were <4 μm. Extracts from outdoor samples reduced human lung cell viability, and multivariate modeling flagged families of potentially toxic substances in a virtual effect-directed analysis. PDMS-foam disks require field calibration to determine their linear sampling rate(s), but current results and applications establish PDMS-foam as a multimodal passive sampler, enabling integrated chemical quantitation, toxicological analysis, and molecular discovery in air.

Authors

Institutions

Publication Details

Journal
Environmental Science & Technology
Published
2026-02-10
DOI
https://doi.org/10.1021/acs.est.5c16613
Citations
1
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
31.09
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Silicone-Foam Passive Air Samplers for Combined Target and Nontarget Chemical Profiling and Toxicity Assessment of Airborne Exposomes

Jean Froment, Stefano Papazian, Daniel Schlesinger, Hongyu Xie et al.
1 citations
Environmental Science & Technology
Indoor Air Quality and Microbial Exposure
31.09
article

Silicone-Foam Passive Air Samplers for Combined Target and Nontarget Chemical Profiling and Toxicity Assessment of Airborne Exposomes

Jean Froment, Stefano Papazian, Daniel Schlesinger, Hongyu Xie, Edouard Pesquet, May Britt Rian, Michael Norman, Bénilde Bonnefille, S B Lee, Boram Kim, J. H. Lee, Young June Jeon, Adrià Sunyer-Caldú, Jonathan W. Martin, Foteini Raptopoulou
article en
1 citations

Abstract

Polluted air is a major global health risk factor, yet the chemical composition and toxicity of airborne gases and particles remain underexplored due to their complexity and difficulties in sampling. We recently introduced how polydimethylsiloxane (PDMS) foam─or silicone foam─can be synthesized for passive air sampling, enabling simple and cost-effective nontarget chemical profiling of indoor air. Here, we demonstrate expanded applications, indoors and outdoors, with commercial PDMS-foam, including for: (i) wide-scope target analysis of >220 priority substances by quantitative liquid- and gas chromatography-high-resolution mass spectrometry, (ii) microscopic characterization and nontarget profiling of accumulated fine particles, and (iii) effect-guided discovery of harmful substances, combining toxicological data with nontarget analysis in silico. Median method quantification limits were 0.12 ng/mL, 90% of target analytes had absolute recoveries between 70 and 130%, and hazardous substances were discovered, including ethylene glycols, insecticides, and UV filters. Microscopy revealed the accumulation of abundant fine particles, and the automated characterization of the fluorescent fraction revealed that most were <4 μm. Extracts from outdoor samples reduced human lung cell viability, and multivariate modeling flagged families of potentially toxic substances in a virtual effect-directed analysis. PDMS-foam disks require field calibration to determine their linear sampling rate(s), but current results and applications establish PDMS-foam as a multimodal passive sampler, enabling integrated chemical quantitation, toxicological analysis, and molecular discovery in air.

Environmental Science & TechnologyVol. 60(7)
Statistics Sweden (SE), Health Effects Institute (US), Natural Environment Research Council (GB), Stockholm University (SE), Science for Life Laboratory (SE), Integrative Medicine Institute (US), Korea Institute of Science and Technology (KR), Centre for Science and Environment (IN)
Openalex Percentile: Top 1%
Indoor Air Quality and Microbial Exposure
31.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.