Utilizing MgO and MgO/Au for the measurement of energy and intensity of X-ray; instruments and materials

Semiconductor materials characterized by wide-bandgaps are well-suitable for measuring and detecting high-energy particles, such as x rays. According to the insulating properties of metal oxides and the sensing capabilities of two-dimensional nanomaterials, magnesium oxide (MgO) becomes a promising sensing material. To change the sensing behavior of composites, metal nanoparticles used to capitalize on their synergistic effects and change in reactions. According to this, magnesium oxide/gold (MgO/Au) nanocomposite was synthesized using facile and straightforward methods, namely laser ablation in liquid and magnetic stirring. In the study of electric response to x ray, it was observed that, compared to the energy change in photons, the MgO/Au nanocomposite shows higher sensitivity to intensity changes in x radiation. In contrast, MgO nanosheets demonstrate sensitivity to energy and intensity changes in radiation. With precise ammeter and appropriate analysis, these materials, when placed in the same device, have the potential to measure the energy and intensity of x rays. It is well established that semiconductors such as MgO with wide-energy-bandgaps exceeding 5 eV can demonstrate resistances in the megaohm range in prepared samples for analysis. Due to this elevated resistance, the electric current flowing through the biased material typically falls within the hundreds of picoamperes (pA). Such low current levels pose significant challenges for measurement using standard and even advanced ammeters, as they are highly susceptible to interference from noise sources. To mitigate this challenge, we have developed and evaluated a circuit designed to supply the necessary bias voltage and accurately measure extremely low electrical currents, specifically at the 10 pA level.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2026-02-01
DOI
https://doi.org/10.1063/5.0302568
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilizing MgO and MgO/Au for the measurement of energy and intensity of X-ray; instruments and materials

Milad Daneshnazar, Atefeh Nasri, Gholamreza Fardipour Raki, Mohsen Khakzad et al.
Review of Scientific Instruments
Radiation Shielding Materials Analysis
article

Utilizing MgO and MgO/Au for the measurement of energy and intensity of X-ray; instruments and materials

Milad Daneshnazar, Atefeh Nasri, Gholamreza Fardipour Raki, Mohsen Khakzad, Babak Jaleh
article en

Abstract

Semiconductor materials characterized by wide-bandgaps are well-suitable for measuring and detecting high-energy particles, such as x rays. According to the insulating properties of metal oxides and the sensing capabilities of two-dimensional nanomaterials, magnesium oxide (MgO) becomes a promising sensing material. To change the sensing behavior of composites, metal nanoparticles used to capitalize on their synergistic effects and change in reactions. According to this, magnesium oxide/gold (MgO/Au) nanocomposite was synthesized using facile and straightforward methods, namely laser ablation in liquid and magnetic stirring. In the study of electric response to x ray, it was observed that, compared to the energy change in photons, the MgO/Au nanocomposite shows higher sensitivity to intensity changes in x radiation. In contrast, MgO nanosheets demonstrate sensitivity to energy and intensity changes in radiation. With precise ammeter and appropriate analysis, these materials, when placed in the same device, have the potential to measure the energy and intensity of x rays. It is well established that semiconductors such as MgO with wide-energy-bandgaps exceeding 5 eV can demonstrate resistances in the megaohm range in prepared samples for analysis. Due to this elevated resistance, the electric current flowing through the biased material typically falls within the hundreds of picoamperes (pA). Such low current levels pose significant challenges for measurement using standard and even advanced ammeters, as they are highly susceptible to interference from noise sources. To mitigate this challenge, we have developed and evaluated a circuit designed to supply the necessary bias voltage and accurately measure extremely low electrical currents, specifically at the 10 pA level.

Review of Scientific InstrumentsVol. 97(2)
The University of Texas at Dallas (US), Bu-Ali Sina University (IR), Institute for Research in Fundamental Sciences (IR)
Affordable and clean energy
Openalex Percentile: Top 62%
Radiation Shielding Materials Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.