Adaptive physiology-informed correction for reliable remote photoplethysmography heart-rate monitoring

Contactless heart rate (HR) monitoring demonstrates significant potential for mobile health and telemedicine, but current remote photoplethysmography (rPPG) approaches remain vulnerable to various noise sources. While existing research has emphasized signal-level enhancement, correcting erroneous HR estimates remains underexplored. We present a plug-and-play adaptive correction algorithm that leverages cardiac dynamics constraints, adjusting HR estimates based on physiological priors of HR elevation and recovery. By mapping HR frequencies to indices and applying adaptive corrections, our method significantly reduces measurement errors with minimal computational load, even under challenging conditions. Across three public datasets, the algorithm increased the proportion of accurate measurements (mean absolute error ≤ 10 beats per minute) from 46.26% to 84.14% (LGI-PPGI), 48.03% to 69.21% (BUAA-MIHR), and 92.22% to 96.67% (UBFC-rPPG), outperforming existing correction techniques. The lightweight design facilitates seamless edge-side integration, providing a scalable solution for enhancing the reliability of contactless HR monitoring in mobile and remote healthcare settings.

Authors

Institutions

Publication Details

Journal
npj Digital Medicine
Published
2026-02-10
DOI
https://doi.org/10.1038/s41746-026-02386-y
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Adaptive physiology-informed correction for reliable remote photoplethysmography heart-rate monitoring

Edmund Y. M. Lam, Yanmin Zhu, Mohamed Elgendi, Yunfei Tian et al.
npj Digital Medicine
Non-Invasive Vital Sign Monitoring
article

Adaptive physiology-informed correction for reliable remote photoplethysmography heart-rate monitoring

Edmund Y. M. Lam, Yanmin Zhu, Mohamed Elgendi, Yunfei Tian, Shuo Li
article en

Abstract

Contactless heart rate (HR) monitoring demonstrates significant potential for mobile health and telemedicine, but current remote photoplethysmography (rPPG) approaches remain vulnerable to various noise sources. While existing research has emphasized signal-level enhancement, correcting erroneous HR estimates remains underexplored. We present a plug-and-play adaptive correction algorithm that leverages cardiac dynamics constraints, adjusting HR estimates based on physiological priors of HR elevation and recovery. By mapping HR frequencies to indices and applying adaptive corrections, our method significantly reduces measurement errors with minimal computational load, even under challenging conditions. Across three public datasets, the algorithm increased the proportion of accurate measurements (mean absolute error ≤ 10 beats per minute) from 46.26% to 84.14% (LGI-PPGI), 48.03% to 69.21% (BUAA-MIHR), and 92.22% to 96.67% (UBFC-rPPG), outperforming existing correction techniques. The lightweight design facilitates seamless edge-side integration, providing a scalable solution for enhancing the reliability of contactless HR monitoring in mobile and remote healthcare settings.

npj Digital MedicineVol. 9(1)
Khalifa University of Science and Technology (AE), University of Hong Kong (HK)
Khalifa University of Science, Technology and Research
Good health and well-being
Openalex Percentile: Top 62%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.