ZnSe based 2D photonic crystal biosensor supported with machine learning for critical blood component detection and diagnosis of hypofibrinogenemia

• A ZnSe-based two-dimensional photonic crystal biosensor is designed for detecting critical blood components. • The sensor enables identification of conditions such as hypofibrinogenemia, chronic renal disease, and artery-related disorders. • Key performance metrics including wavelength sensitivity, quality factor, and figure of merit are evaluated using FDTD simulations. • A four-cavity layout is investigated to enhance spectral separation between analytes. • Machine learning models (polynomial regression, gradient boost, XGBoost, K-nearest neighbor, Random Forest) are deployed to predict optical parameters. Biosensor for detecting critical blood components using zinc selenide (ZnSe) two dimensional photonic crystal is presented. The proposed sensor is expected to be a resourceful approach in identifying hypofibrinogenemia, chronic renal disease and artery related disorders. Wavelength sensitivity, quality factor (QF) and figure of merit are the defining metrics of the sensor which are being evaluated. Design and implementation of the sensor is done using FDTD (Finite difference time domain) method. Four cavity layout is being investigated in the sensor topology to refine the spectral separation between the analytes. Machine learning (ML) platform is deployed for predicting optical parameters such as wavelength sensitivity and peak wavelength. ML models such as polynomial regression, gradient boost, XGboost regression, K-nearest neighbor regression and Random Forest are leveraged to predict the metrics. R 2 score, Mean squared error (MSE) and mean absolute error (MAE) are evaluated for each model to comprehend the accuracy in predicting sensor metrics.

Authors

Institutions

Publication Details

Journal
Optics and Lasers in Engineering
Published
2026-02-10
DOI
https://doi.org/10.1016/j.optlaseng.2026.109678
Primary Topic
Photonic Crystals and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ZnSe based 2D photonic crystal biosensor supported with machine learning for critical blood component detection and diagnosis of hypofibrinogenemia

N. Harikrishnan, Sangeetha A
Optics and Lasers in Engineering
Photonic Crystals and Applications
article

ZnSe based 2D photonic crystal biosensor supported with machine learning for critical blood component detection and diagnosis of hypofibrinogenemia

N. Harikrishnan, Sangeetha A
article en

Abstract

• A ZnSe-based two-dimensional photonic crystal biosensor is designed for detecting critical blood components. • The sensor enables identification of conditions such as hypofibrinogenemia, chronic renal disease, and artery-related disorders. • Key performance metrics including wavelength sensitivity, quality factor, and figure of merit are evaluated using FDTD simulations. • A four-cavity layout is investigated to enhance spectral separation between analytes. • Machine learning models (polynomial regression, gradient boost, XGBoost, K-nearest neighbor, Random Forest) are deployed to predict optical parameters. Biosensor for detecting critical blood components using zinc selenide (ZnSe) two dimensional photonic crystal is presented. The proposed sensor is expected to be a resourceful approach in identifying hypofibrinogenemia, chronic renal disease and artery related disorders. Wavelength sensitivity, quality factor (QF) and figure of merit are the defining metrics of the sensor which are being evaluated. Design and implementation of the sensor is done using FDTD (Finite difference time domain) method. Four cavity layout is being investigated in the sensor topology to refine the spectral separation between the analytes. Machine learning (ML) platform is deployed for predicting optical parameters such as wavelength sensitivity and peak wavelength. ML models such as polynomial regression, gradient boost, XGboost regression, K-nearest neighbor regression and Random Forest are leveraged to predict the metrics. R 2 score, Mean squared error (MSE) and mean absolute error (MAE) are evaluated for each model to comprehend the accuracy in predicting sensor metrics.

Optics and Lasers in EngineeringVol. 201
Vellore Institute of Technology University (IN)
Openalex Percentile: Top 59%
Photonic Crystals and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.