Our research on quantitative pre-control of indoor air quality in the design stage

Abstract Numerous synthetic materials are widely used in indoor environments. Some of these materials emit hazardous volatile organic compounds (VOCs), such as formaldehyde and benzene, which are recognized carcinogens. Moreover, outdoor air pollutants like PM 2.5 infiltrate indoor spaces. Both indoor emission sources and outdoor infiltration significantly degrade indoor air quality (IAQ), contributing to public health concerns in China over recent decades. Quantitative pre-control of IAQ through appropriate engineering interventions during the design phase represents the most cost-effective strategy to ensure occupants breathe healthy air indoors. This paper presents a systematic summary of our research conducted over the past two decades on the quantitative pre-control of IAQ using engineering-based methods during the building and indoor environment design phase. Our findings primarily address the following key aspects of quantitative pre-control of IAQ: 1) developing a framework for the quantitative pre-control of IAQ; 2) implementing quantitative pre-control strategies for indoor-generated indoor air pollutants (IAPs); 3) applying energy- and cost-effective approaches to IAQ pre-control; 4) identifying target indoor-origin indoor air pollutants (IAPs) based on their individual disease burdens; and 5) establishing IAP concentration thresholds according to quantitative assessments of net economic benefit (NEB). Quantitative pre-control of IAQ requires not only interdisciplinary collaboration to elucidate mechanisms across the full pathway—from pollution sources to human exposure—but also multi-industry coordination to ensure consistency in engineering control techniques and standards throughout the IAQ management chain. Our findings establish the essential scientific and technical foundation for such quantitative pre-control through these integrated collaborations.

Authors

Institutions

Publication Details

Journal
Interdisciplinary Nursing Research
Published
2026-02-09
DOI
https://doi.org/10.1097/nr9.0000000000000118
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Our research on quantitative pre-control of indoor air quality in the design stage

Jingya Wei, Yi Xu, Charles J. Weschler, Haimei Wang et al.
Interdisciplinary Nursing Research
Indoor Air Quality and Microbial Exposure
article

Our research on quantitative pre-control of indoor air quality in the design stage

Jingya Wei, Yi Xu, Charles J. Weschler, Haimei Wang, Shu Wang, Rui You, Yinping Zhang
article en

Abstract

Abstract Numerous synthetic materials are widely used in indoor environments. Some of these materials emit hazardous volatile organic compounds (VOCs), such as formaldehyde and benzene, which are recognized carcinogens. Moreover, outdoor air pollutants like PM 2.5 infiltrate indoor spaces. Both indoor emission sources and outdoor infiltration significantly degrade indoor air quality (IAQ), contributing to public health concerns in China over recent decades. Quantitative pre-control of IAQ through appropriate engineering interventions during the design phase represents the most cost-effective strategy to ensure occupants breathe healthy air indoors. This paper presents a systematic summary of our research conducted over the past two decades on the quantitative pre-control of IAQ using engineering-based methods during the building and indoor environment design phase. Our findings primarily address the following key aspects of quantitative pre-control of IAQ: 1) developing a framework for the quantitative pre-control of IAQ; 2) implementing quantitative pre-control strategies for indoor-generated indoor air pollutants (IAPs); 3) applying energy- and cost-effective approaches to IAQ pre-control; 4) identifying target indoor-origin indoor air pollutants (IAPs) based on their individual disease burdens; and 5) establishing IAP concentration thresholds according to quantitative assessments of net economic benefit (NEB). Quantitative pre-control of IAQ requires not only interdisciplinary collaboration to elucidate mechanisms across the full pathway—from pollution sources to human exposure—but also multi-industry coordination to ensure consistency in engineering control techniques and standards throughout the IAQ management chain. Our findings establish the essential scientific and technical foundation for such quantitative pre-control through these integrated collaborations.

Interdisciplinary Nursing Research
Rutgers, The State University of New Jersey (US), Beijing Institute of Technology (CN), Environmental and Occupational Health Sciences Institute (US), State Development & Investment Corporation (China) (CN), Tsinghua University (CN)
Openalex Percentile: Top 64%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.