Comparison of Molecule Clearance and Pro-Inflammatory Markers Between High-Flux and Medium Cut-Off Dialyzers (ELISIO™ 21): A Crossover Pilot Study

Background: Chronic kidney disease (CKD) is increasingly prevalent, leading to more patients requiring hemodialysis. Medium cut-off (MCO) membranes, such as the ELISIO™ HX dialyzer, may enhance middle-to-large molecule removal and reduce inflammation compared with conventional high-flux membranes. This study evaluated the efficacy and safety of ELISIO™ HX versus a standard high-flux dialyzer (Toraylight NS-21S) in terms of molecular reduction rate and inflammation. Methods: We performed a single-center, prospective, randomized crossover study with 12 hemodialysis patients, each treated with Toraylight NS-21S and ELISIO™ HX over four weeks. Pre- and post-dialysis levels of urea, creatinine, albumin, creatine kinase, phosphorus, parathyroid hormone, C-reactive protein (CRP), procalcitonin, interleukin 6 (IL-6), and β2-microglobulin were measured. Pre–post differences were assessed using dialyzer analysis, period-effect and carryover analysis, and non-inferiority analysis. Results: ELISIO™ HX was non-inferior to Toraylight NS-21S for creatinine, urea, phosphorus, procalcitonin, and β2-microglobulin. No significant serum albumin changes were observed with either dialyzer. Adverse events were infrequent and comparable between the dialyzers. Conclusions: ELISIO™ HX appears non-inferior to Toraylight NS-21S and suggests good safety and tolerability. These findings should be interpreted with caution given the study’s limited power.

Authors

Institutions

Publication Details

Journal
Kidney and Dialysis
Published
2026-02-10
DOI
https://doi.org/10.3390/kidneydial6010010
Primary Topic
Dialysis and Renal Disease Management
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Molecule Clearance and Pro-Inflammatory Markers Between High-Flux and Medium Cut-Off Dialyzers (ELISIO™ 21): A Crossover Pilot Study

M. Eugenia Palacios-Gómez, Javier Ramírez-Santos, María Paloma Flores-Paloma, Francisco Javier González-Martínez et al.
Kidney and Dialysis
Dialysis and Renal Disease Management
article

Comparison of Molecule Clearance and Pro-Inflammatory Markers Between High-Flux and Medium Cut-Off Dialyzers (ELISIO™ 21): A Crossover Pilot Study

M. Eugenia Palacios-Gómez, Javier Ramírez-Santos, María Paloma Flores-Paloma, Francisco Javier González-Martínez, Paula López-Sánchez, Manuel David Sánchez-Martos, Llenalia Gordillo-García
article en

Abstract

Background: Chronic kidney disease (CKD) is increasingly prevalent, leading to more patients requiring hemodialysis. Medium cut-off (MCO) membranes, such as the ELISIO™ HX dialyzer, may enhance middle-to-large molecule removal and reduce inflammation compared with conventional high-flux membranes. This study evaluated the efficacy and safety of ELISIO™ HX versus a standard high-flux dialyzer (Toraylight NS-21S) in terms of molecular reduction rate and inflammation. Methods: We performed a single-center, prospective, randomized crossover study with 12 hemodialysis patients, each treated with Toraylight NS-21S and ELISIO™ HX over four weeks. Pre- and post-dialysis levels of urea, creatinine, albumin, creatine kinase, phosphorus, parathyroid hormone, C-reactive protein (CRP), procalcitonin, interleukin 6 (IL-6), and β2-microglobulin were measured. Pre–post differences were assessed using dialyzer analysis, period-effect and carryover analysis, and non-inferiority analysis. Results: ELISIO™ HX was non-inferior to Toraylight NS-21S for creatinine, urea, phosphorus, procalcitonin, and β2-microglobulin. No significant serum albumin changes were observed with either dialyzer. Adverse events were infrequent and comparable between the dialyzers. Conclusions: ELISIO™ HX appears non-inferior to Toraylight NS-21S and suggests good safety and tolerability. These findings should be interpreted with caution given the study’s limited power.

Kidney and DialysisVol. 6(1)
Andalusian Health Service (ES), Hospital Universitario Puerta de Hierro Majadahonda (ES), Complejo Hospitalario Torrecárdenas (ES)
Google
Good health and well-being
Openalex Percentile: Top 66%
Dialysis and Renal Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.