Ductile crack initiation in welded connections with highly dissipative panel zones

Shear yielding enables beam-to-column connections in capacity-designed steel moment frames to dissipate energy and remain stable at lateral drifts up to 4% rad, as long as ductile fracture does not compromise their hysteretic behavior at lower drift levels. This paper characterizes the fracture potential of welded unreinforced flange-welded web (WUF-W) connections designed with such an alternative design concept that defies the current status quo of pre-qualified welded connections. The analysis relies on state-of-the-art micromechanics based fracture models along with detailed mechanical testing and scanning electron microscopy of samples extracted from WUF-W connections exhibiting ductile fracture originating at the kink points of their panel zone at deformation demands characteristic of earthquakes with a low probability of occurrence. The analysis results demonstrate that while the origin of ductile fracture is near the complete joint penetration (CJP) weld toe of the beam flange-to-column face joint, the overall hysteretic behavior of the connections meet the pre-qualification limits established in current seismic standards. Leaving a customized beveled backing bar in place after completing the CJP welds does not elevate the risk of ductile fracture at this location, thus enabling a more straightforward fabrication process than the current practice. The simulation of hypothetical extreme earthquake loading scenarios demonstrates that, the examined WUF-W connections are not prone to ductile fracture till at least 6% rad while achieving instability-free hysteretic response. • The ductile fracture initiation of welded connections (WUF-W) with highly dissipative panel zones is investigated. • Rigorous fracture modeling including multiple tests for micromechanics-based models is conducted. • WUF-W connections with inelastic panel zones are resilient to ductile fracture. • Simplified weld details can be used to alleviate the fracture potential in welded connections.

Authors

Institutions

Publication Details

Journal
Journal of Constructional Steel Research
Published
2026-02-10
DOI
https://doi.org/10.1016/j.jcsr.2026.110258
Primary Topic
Metal Forming Simulation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ductile crack initiation in welded connections with highly dissipative panel zones

Dimitrios G. Lignos, Andronikos Skiadopoulos
Journal of Constructional Steel Research
Metal Forming Simulation Techniques
article

Ductile crack initiation in welded connections with highly dissipative panel zones

Dimitrios G. Lignos, Andronikos Skiadopoulos
article en

Abstract

Shear yielding enables beam-to-column connections in capacity-designed steel moment frames to dissipate energy and remain stable at lateral drifts up to 4% rad, as long as ductile fracture does not compromise their hysteretic behavior at lower drift levels. This paper characterizes the fracture potential of welded unreinforced flange-welded web (WUF-W) connections designed with such an alternative design concept that defies the current status quo of pre-qualified welded connections. The analysis relies on state-of-the-art micromechanics based fracture models along with detailed mechanical testing and scanning electron microscopy of samples extracted from WUF-W connections exhibiting ductile fracture originating at the kink points of their panel zone at deformation demands characteristic of earthquakes with a low probability of occurrence. The analysis results demonstrate that while the origin of ductile fracture is near the complete joint penetration (CJP) weld toe of the beam flange-to-column face joint, the overall hysteretic behavior of the connections meet the pre-qualification limits established in current seismic standards. Leaving a customized beveled backing bar in place after completing the CJP welds does not elevate the risk of ductile fracture at this location, thus enabling a more straightforward fabrication process than the current practice. The simulation of hypothetical extreme earthquake loading scenarios demonstrates that, the examined WUF-W connections are not prone to ductile fracture till at least 6% rad while achieving instability-free hysteretic response. • The ductile fracture initiation of welded connections (WUF-W) with highly dissipative panel zones is investigated. • Rigorous fracture modeling including multiple tests for micromechanics-based models is conducted. • WUF-W connections with inelastic panel zones are resilient to ductile fracture. • Simplified weld details can be used to alleviate the fracture potential in welded connections.

Journal of Constructional Steel ResearchVol. 240
École Polytechnique Fédérale de Lausanne (CH), Stanford University (US)
Sustainable cities and communities
Openalex Percentile: Top 62%
Metal Forming Simulation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.