An Inline System for Air-in-Line Detection and Automatic Occlusion in Peripheral Intravenous Therapy

The presence of air within intravenous (IV) infusion tubing represents a recognized safety concern in routine peripheral IV therapy, particularly when infusion sources run dry or lines are left unattended. While air-in-line detection systems are available in clinical practice, these approaches commonly involve alarm-based notification following detection events. This alarm-dependent approach leaves a gap in automatic mitigation and end-of-infusion control during common clinical workflows. This work presents the design and operating principle of a compact, low-cost, battery-powered air-in-line detection system intended for peripheral IV tubing. The device employs an infrared-based sensing approach to continuously monitor tubing for the presence of air and for conditions consistent with end of infusion, such as depletion of the fluid source. Upon detection, the system automatically actuates a mechanical occlusion mechanism to halt flow while simultaneously providing notification to clinical staff. Benchtop evaluation of the proposed system demonstrated a consistent change in infrared sensor output when air was present within standard intravenous tubing compared to fluid-filled conditions. Detection of air-in-line or end-of-infusion events triggered the control logic, resulting in activation of a user notification and engagement of the motor-driven clamping mechanism designed to interrupt flow. These observations support the feasibility of integrating optical air-in-line detection with automatic flow occlusion within a compact, pump-independent inline system. Existing air-in-line detection approaches typically involve alarm generation to notify clinical staff. The proposed system addresses this limitation by combining continuous monitoring with automatic physical interruption of flow, providing an additional layer of safety and an automated end-of-infusion shutoff mechanism. This approach has the potential to improve IV safety and reduce clinical workload during routine peripheral intravenous therapy.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2026-02-09
DOI
https://doi.org/10.7759/cureus.103291
Primary Topic
Intravenous Infusion Technology and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Inline System for Air-in-Line Detection and Automatic Occlusion in Peripheral Intravenous Therapy

Drin Rrmoku
Cureus
Intravenous Infusion Technology and Safety
article

An Inline System for Air-in-Line Detection and Automatic Occlusion in Peripheral Intravenous Therapy

Drin Rrmoku
article en

Abstract

The presence of air within intravenous (IV) infusion tubing represents a recognized safety concern in routine peripheral IV therapy, particularly when infusion sources run dry or lines are left unattended. While air-in-line detection systems are available in clinical practice, these approaches commonly involve alarm-based notification following detection events. This alarm-dependent approach leaves a gap in automatic mitigation and end-of-infusion control during common clinical workflows. This work presents the design and operating principle of a compact, low-cost, battery-powered air-in-line detection system intended for peripheral IV tubing. The device employs an infrared-based sensing approach to continuously monitor tubing for the presence of air and for conditions consistent with end of infusion, such as depletion of the fluid source. Upon detection, the system automatically actuates a mechanical occlusion mechanism to halt flow while simultaneously providing notification to clinical staff. Benchtop evaluation of the proposed system demonstrated a consistent change in infrared sensor output when air was present within standard intravenous tubing compared to fluid-filled conditions. Detection of air-in-line or end-of-infusion events triggered the control logic, resulting in activation of a user notification and engagement of the motor-driven clamping mechanism designed to interrupt flow. These observations support the feasibility of integrating optical air-in-line detection with automatic flow occlusion within a compact, pump-independent inline system. Existing air-in-line detection approaches typically involve alarm generation to notify clinical staff. The proposed system addresses this limitation by combining continuous monitoring with automatic physical interruption of flow, providing an additional layer of safety and an automated end-of-infusion shutoff mechanism. This approach has the potential to improve IV safety and reduce clinical workload during routine peripheral intravenous therapy.

CureusVol. 18(2)
University of Prishtina (XK)
Openalex Percentile: Top 62%
Intravenous Infusion Technology and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.