Optics-based method for enhancing spectroscopic calibration model development

Spectrometric calibration is a challenge for every application because a large number and variability of reference samples are required to develop an accurate and robust model. This study investigates the potential of improving spectrometer calibration by using physically simulated spectra to enhance the calibration data set and perform out-of-range predictions. For this purpose, 56 liquid samples covering a wide range of absorption and scattering properties are measured with a double integrating sphere setup and visible spectrometers. A Kubelka-Munk optical model is used to simulate the samples reflectance and transmittance spectra. A simple method of calibration enhancement is introduced, and its benefits are evaluated with a partial least squares regression model, in comparison to a classical calibration approach. Two cases are studied, one with wide variability among reference samples and one with a limited range. The proposed method shows promising results, especially in the second, hardest case. A further study is done to evaluate the impact of simulated data quantity on the models' results. It was found that the performances reach a maximum when the ratio between measured and simulated spectra is 1:2.

Authors

Institutions

Publication Details

Journal
Applied Optics
Published
2026-02-09
DOI
https://doi.org/10.1364/ao.578186
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optics-based method for enhancing spectroscopic calibration model development

Davinia Brouckaert, Fabien Chauchard, Daphné Héran, Simon Pinault et al.
Applied Optics
Spectroscopy and Chemometric Analyses
article

Optics-based method for enhancing spectroscopic calibration model development

Davinia Brouckaert, Fabien Chauchard, Daphné Héran, Simon Pinault, Ryad Bendoula
article en

Abstract

Spectrometric calibration is a challenge for every application because a large number and variability of reference samples are required to develop an accurate and robust model. This study investigates the potential of improving spectrometer calibration by using physically simulated spectra to enhance the calibration data set and perform out-of-range predictions. For this purpose, 56 liquid samples covering a wide range of absorption and scattering properties are measured with a double integrating sphere setup and visible spectrometers. A Kubelka-Munk optical model is used to simulate the samples reflectance and transmittance spectra. A simple method of calibration enhancement is introduced, and its benefits are evaluated with a partial least squares regression model, in comparison to a classical calibration approach. Two cases are studied, one with wide variability among reference samples and one with a limited range. The proposed method shows promising results, especially in the second, hardest case. A further study is done to evaluate the impact of simulated data quantity on the models' results. It was found that the performances reach a maximum when the ratio between measured and simulated spectra is 1:2.

Applied OpticsVol. 65(8)
Université de Montpellier (FR), Institut Agro Montpellier (FR), Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement (FR), Château de Longchamp (FR), Technologies & méthodes pour les agricultures de demain (FR), L'Institut Agro (FR)
Openalex Percentile: Top 59%
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.