Dynamics of lead release from pipes containing PbO2 in response to free chlorine depletion during water stagnation

Lead(IV) oxide (PbO<sub>2</sub>) is an important lead corrosion product found on many lead service lines (LSLs). Because of its low solubility, PbO<sub>2</sub> formation on the surface of lead pipes can potentially minimize the release of lead to water. However, PbO<sub>2</sub> is only stable in the presence of free chlorine, and it undergoes reductive dissolution in the absence of free chlorine. A laboratory-scale pipe loop test with harvested LSLs that had pipe scales rich in PbO<sub>2</sub> investigated how the PbO<sub>2</sub>-rich layer responded to free chlorine depletion. Depletion of free chlorine resulted in substantial increases in both dissolved and total lead concentrations. However, the rise in dissolved lead was not immediate and was delayed by 1-2 days, eventually exceeding 15 μg/L after chlorine depletion. Total lead release posed a greater concern, characterized by sporadic and high concentrations (>100 μg/L) when free chlorine was depleted. A free chlorine concentration of 0.4 mg/L as Cl<sub>2</sub> was able to maintain PbO<sub>2</sub> stability for the full duration of a 10-day experiment. Although the reductive dissolution of PbO<sub>2</sub> after free chlorine decay resulted in substantial increases in lead concentrations in the water, the vast majority (greater than 99.93 %) of the PbO<sub>2</sub> remained in the scale. This research provides new information on the effects of key factors on the reductive dissolution of PbO<sub>2</sub> present in the scales of LSLs, and it offers insights into how PbO<sub>2</sub> formation and stability can govern the dynamics of lead concentrations in water delivered through lead pipes.

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Materials
Published
2026-02-01
DOI
https://doi.org/10.1016/j.jhazmat.2026.141438
Primary Topic
Water Treatment and Disinfection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamics of lead release from pipes containing PbO2 in response to free chlorine depletion during water stagnation

Daniel E. Giammar, Yao Ma, Zehua Wang, Roger B. Arnold
Journal of Hazardous Materials
Water Treatment and Disinfection
article

Dynamics of lead release from pipes containing PbO2 in response to free chlorine depletion during water stagnation

Daniel E. Giammar, Yao Ma, Zehua Wang, Roger B. Arnold
article en

Abstract

Lead(IV) oxide (PbO<sub>2</sub>) is an important lead corrosion product found on many lead service lines (LSLs). Because of its low solubility, PbO<sub>2</sub> formation on the surface of lead pipes can potentially minimize the release of lead to water. However, PbO<sub>2</sub> is only stable in the presence of free chlorine, and it undergoes reductive dissolution in the absence of free chlorine. A laboratory-scale pipe loop test with harvested LSLs that had pipe scales rich in PbO<sub>2</sub> investigated how the PbO<sub>2</sub>-rich layer responded to free chlorine depletion. Depletion of free chlorine resulted in substantial increases in both dissolved and total lead concentrations. However, the rise in dissolved lead was not immediate and was delayed by 1-2 days, eventually exceeding 15 μg/L after chlorine depletion. Total lead release posed a greater concern, characterized by sporadic and high concentrations (>100 μg/L) when free chlorine was depleted. A free chlorine concentration of 0.4 mg/L as Cl<sub>2</sub> was able to maintain PbO<sub>2</sub> stability for the full duration of a 10-day experiment. Although the reductive dissolution of PbO<sub>2</sub> after free chlorine decay resulted in substantial increases in lead concentrations in the water, the vast majority (greater than 99.93 %) of the PbO<sub>2</sub> remained in the scale. This research provides new information on the effects of key factors on the reductive dissolution of PbO<sub>2</sub> present in the scales of LSLs, and it offers insights into how PbO<sub>2</sub> formation and stability can govern the dynamics of lead concentrations in water delivered through lead pipes.

Journal of Hazardous MaterialsVol. 504
Washington University in St. Louis (US), Hazen and Sawyer (United States) (US)
Clean water and sanitation
Openalex Percentile: Top 64%
Water Treatment and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.