An innovative power converter based technique for on-site photovoltaic I-V characterization under natural irradiance

This paper presents a standalone PV curve tracer designed to extract current-voltage (I-V) and power-voltage (P-V) characteristics, as well as the five parameters of a Multiple-Diode Model (MDM) with identical diodes, effectively reducing it to a single-diode model for parameter extraction, under real sunlight conditions. The system consists of a custom-built synchronous boost converter operating as a programmable electronic load, where the duty cycle of the PWM signal regulates the equivalent resistance. Integrated with voltage and current sensors, along with external solar irradiance and temperature sensors, the system enables the automatic extraction of I-V and P-V curves for PV panels up to 300 W. Experiments were conducted on a 12-cell ET-M53630WW PV panel (V<sub>OC</sub> = 21.52 V, I<sub>SC</sub> = 1.8 A, V<sub>MP</sub> = 17.72 V, I<sub>MP</sub> = 1.69 A and P<sub>MP</sub> = 30 W), demonstrating the system's performance under realistic operating conditions. A nonlinear least squares fitting algorithm based on the Levenberg-Marquardt method processes the extracted curves to determine the five key parameters of the PV panel with high precision. Experimental validation demonstrated that the estimated and measured I-V curves are nearly identical, with a worst-case current deviation of only 41.5 mA. The reconstructed P-V curve at standard test conditions (G = 1000 W/m², T = 298.15 K) closely matched the manufacturer's datasheet, yielding a maximum power of 27 W compared to the rated 30 W. These results highlight the accuracy of the proposed methodology in parameter extraction and its potential application in PV performance monitoring, degradation analysis, and educational use.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-09
DOI
https://doi.org/10.1038/s41598-026-39626-w
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An innovative power converter based technique for on-site photovoltaic I-V characterization under natural irradiance

Kamal Hirech, Firyal Latrache, Badre Bossoufi, Ilias Atmane et al.
Scientific Reports
Photovoltaic System Optimization Techniques
article

An innovative power converter based technique for on-site photovoltaic I-V characterization under natural irradiance

Kamal Hirech, Firyal Latrache, Badre Bossoufi, Ilias Atmane, Mostafa El Ouariachi, Mourad Yessef, Mohammed Rhiat, Z. M.S. El-Barbary, Saad A. Alqahtani, Mustapha Melhaoui, Imane Ihsane
article en

Abstract

This paper presents a standalone PV curve tracer designed to extract current-voltage (I-V) and power-voltage (P-V) characteristics, as well as the five parameters of a Multiple-Diode Model (MDM) with identical diodes, effectively reducing it to a single-diode model for parameter extraction, under real sunlight conditions. The system consists of a custom-built synchronous boost converter operating as a programmable electronic load, where the duty cycle of the PWM signal regulates the equivalent resistance. Integrated with voltage and current sensors, along with external solar irradiance and temperature sensors, the system enables the automatic extraction of I-V and P-V curves for PV panels up to 300 W. Experiments were conducted on a 12-cell ET-M53630WW PV panel (V<sub>OC</sub> = 21.52 V, I<sub>SC</sub> = 1.8 A, V<sub>MP</sub> = 17.72 V, I<sub>MP</sub> = 1.69 A and P<sub>MP</sub> = 30 W), demonstrating the system's performance under realistic operating conditions. A nonlinear least squares fitting algorithm based on the Levenberg-Marquardt method processes the extracted curves to determine the five key parameters of the PV panel with high precision. Experimental validation demonstrated that the estimated and measured I-V curves are nearly identical, with a worst-case current deviation of only 41.5 mA. The reconstructed P-V curve at standard test conditions (G = 1000 W/m², T = 298.15 K) closely matched the manufacturer's datasheet, yielding a maximum power of 27 W compared to the rated 30 W. These results highlight the accuracy of the proposed methodology in parameter extraction and its potential application in PV performance monitoring, degradation analysis, and educational use.

Scientific ReportsVol. 16(1)
Cadi Ayyad University (MA), Mohammed V University (MA), Kafrelsheikh University (EG), Mohamed I University (MA), Institut des Hautes Études Bancaires et Financières (MA), Centre Hospitalo-Universitaire Mohammed VI d'Oujda (MA), Centre Hospitalier Saint-Nazaire (FR), Sidi Mohamed Ben Abdellah University (MA), King Khalid University (SA)
King Khalid University
Affordable and clean energy
Openalex Percentile: Top 63%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.