Optical Monitoring of EDTA-Induced Bone Demineralization Using Collimated Transmittance Measurements

Abstract Osteoporosis is a widespread chronic metabolic bone disease. It has developed into a severe public health problem, especially for older people. Preventing fractures caused by osteoporosis and enhancing patient experiences require early identification of bone mineral loss. The commercially available technologies for diagnosing osteoporosis are costly and may trigger cell mutation. Therefore, non-invasive treatments have received great attention. This work explores the potential of employing optical collimated transmittance at 660, 785, and 980 nm to monitor progressive mineral loss in EDTA-treated chicken bone samples. Over the course of six weeks, 20 samples (10 diaphysis and 10 epiphysis) were measured weekly. Transmittance was elevated following demineralisation, particularly at 980 nm, which increased by 190%. The receiver operating characteristic (ROC) analysis produced area under the curve (AUC) values ranging from 0.834 to 0.996 (95% CI), demonstrating strong discrimination between baseline and demineralised states. These results show that near-infrared optical transmission is sensitive to mineral loss and has the potential to be used for low-cost bone assessments. Although EDTA-induced demineralisation does not fully recreate the complicated pathophysiology of clinical osteoporosis, this simplified model serves as a preliminary platform for assessing optical signals associated with mineral loss.

Authors

Institutions

Publication Details

Journal
Journal of Nondestructive Evaluation
Published
2026-02-09
DOI
https://doi.org/10.1007/s10921-025-01325-3
Primary Topic
Bone health and osteoporosis research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical Monitoring of EDTA-Induced Bone Demineralization Using Collimated Transmittance Measurements

Omnia Hamdy, Haitham S. Mohammed, Merna Magdy
Journal of Nondestructive Evaluation
Bone health and osteoporosis research
article

Optical Monitoring of EDTA-Induced Bone Demineralization Using Collimated Transmittance Measurements

Omnia Hamdy, Haitham S. Mohammed, Merna Magdy
article en

Abstract

Abstract Osteoporosis is a widespread chronic metabolic bone disease. It has developed into a severe public health problem, especially for older people. Preventing fractures caused by osteoporosis and enhancing patient experiences require early identification of bone mineral loss. The commercially available technologies for diagnosing osteoporosis are costly and may trigger cell mutation. Therefore, non-invasive treatments have received great attention. This work explores the potential of employing optical collimated transmittance at 660, 785, and 980 nm to monitor progressive mineral loss in EDTA-treated chicken bone samples. Over the course of six weeks, 20 samples (10 diaphysis and 10 epiphysis) were measured weekly. Transmittance was elevated following demineralisation, particularly at 980 nm, which increased by 190%. The receiver operating characteristic (ROC) analysis produced area under the curve (AUC) values ranging from 0.834 to 0.996 (95% CI), demonstrating strong discrimination between baseline and demineralised states. These results show that near-infrared optical transmission is sensitive to mineral loss and has the potential to be used for low-cost bone assessments. Although EDTA-induced demineralisation does not fully recreate the complicated pathophysiology of clinical osteoporosis, this simplified model serves as a preliminary platform for assessing optical signals associated with mineral loss.

Journal of Nondestructive EvaluationVol. 45(1)
Cairo University (EG)
Peace, Justice and strong institutions
Openalex Percentile: Top 63%
Bone health and osteoporosis research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.