Increasing the sensitivity of a surface plasmon resonance sensor using Ti3C2 MXene

Sensors based on the phenomenon of surface plasmon resonance have limited sensitivity, up to 123 degrees per refractive index unit (RIU), which restricts their applicability in detecting subtle changes in biological media (around 10–5 RIU). To address this, a sensor dependent on the Kretschmann–Reather configuration was modified using Ti3C2 MXene material. The sensor was modeled using the finite element method (FEM), yielding the dependence of the wave reflectance on the angle of incidence. Founded on these results, the sensitivity of the sensor was calculated and demonstrated a 10% improvement compared to the conventional Kretschmann–Reather configuration. In addition, human biological real-world samples were modeled using refractive index data, and the error of the proposed approach was determined to be approximately 3%.

Authors

Institutions

Publication Details

Journal
Low Temperature Physics
Published
2026-02-01
DOI
https://doi.org/10.1063/10.0042358
Primary Topic
Plasmonic and Surface Plasmon Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Increasing the sensitivity of a surface plasmon resonance sensor using Ti3C2 MXene

R. G. Terekhov, Z. E. Eremenko, Sergii Kulish
Low Temperature Physics
Plasmonic and Surface Plasmon Research
article

Increasing the sensitivity of a surface plasmon resonance sensor using Ti3C2 MXene

R. G. Terekhov, Z. E. Eremenko, Sergii Kulish
article en

Abstract

Sensors based on the phenomenon of surface plasmon resonance have limited sensitivity, up to 123 degrees per refractive index unit (RIU), which restricts their applicability in detecting subtle changes in biological media (around 10–5 RIU). To address this, a sensor dependent on the Kretschmann–Reather configuration was modified using Ti3C2 MXene material. The sensor was modeled using the finite element method (FEM), yielding the dependence of the wave reflectance on the angle of incidence. Founded on these results, the sensitivity of the sensor was calculated and demonstrated a 10% improvement compared to the conventional Kretschmann–Reather configuration. In addition, human biological real-world samples were modeled using refractive index data, and the error of the proposed approach was determined to be approximately 3%.

Low Temperature PhysicsVol. 52(2)
National Aerospace University – Kharkiv Aviation Institute (UA), Leibniz Institute for Solid State and Materials Research (DE), O.Ya. Usikov Institute for Radiophysics and Electronics (UA), Institute of Radiophysics and Electronics (AM)
Openalex Percentile: Top 62%
Plasmonic and Surface Plasmon Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Increasing the sensitivity of a surface plasmon resonance sensor using Ti3C2 MXene — R. G. Terekhov, Z. E. Eremenko, et al. · Low Temperature Physics (2026) | TGRS Research Map | TGRS