MR-Linac–Based SBRT for Prostate Cancer: Dosimetric Benefits for Urethral Sparing Compared to VMAT and Tomotherapy

<b>Background</b>: Stereotactic body radiotherapy (SBRT) for prostate cancer delivers high doses in few fractions but poses challenges in sparing adjacent organs at risk (OARs), particularly the intra-prostate urethra, bladder, rectum and penile bulb. Magnetic resonance-guided radiotherapy (MRgRT) using MR-Linac offers superior soft-tissue visualization and daily adaptive planning, potentially reducing OAR dose while maintaining target coverage. This study aimed to compare dose-volume parameters among MR-Linac (ML), volumetric modulated arc therapy (VMAT), and Tomotherapy (HT) plans for prostate SBRT. <b>Methods</b>: Thirty patients with localized prostate cancer were retrospectively analyzed. For each patient, three plans were generated: ML, VMAT and HT, using identical prescription and planning objectives. Dose-volume histogram (DVH) metrics were evaluated for clinical target volume (CTV), planning target volume (PTV), and OARs. Statistical comparisons were performed using non-parametric Friedman's Test with post hoc Bonferroni test, with significance set at a <i>p</i> < 0.05. <b>Results</b>: CTV coverage was comparable across all modalities. ML achieved significantly higher PTV Dmin and near-maximum doses compared to VMAT and HT. Notably, ML provided substantial urethral sparing, reducing Dmax and Dmean by approximately 3.3 Gy compared to both VMAT and HT (<i>p</i> < 0.001). Rectal dose metrics were also lower with ML, while bladder and penile bulb doses showed minor increases (<3.5 Gy), considered clinically negligible. Femoral head doses were reduced in ML plans. <b>Conclusions</b>: MR-Linac planning for prostate SBRT offers meaningful dosimetric advantages, particularly in intra-prostate urethra urethral dose reduction, without compromising target coverage. These findings support incorporating MR-guided adaptive workflows into SBRT protocols to enhance OAR protection and potentially reduce treatment-related toxicity.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2026-02-09
DOI
https://doi.org/10.3390/cancers18040568
Primary Topic
Prostate Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

MR-Linac–Based SBRT for Prostate Cancer: Dosimetric Benefits for Urethral Sparing Compared to VMAT and Tomotherapy

Y. Nip, Gavin C. K. Chan, K. P. Fong, Eva Y. W. Cheung et al.
Cancers
Prostate Cancer Diagnosis and Treatment
article

MR-Linac–Based SBRT for Prostate Cancer: Dosimetric Benefits for Urethral Sparing Compared to VMAT and Tomotherapy

Y. Nip, Gavin C. K. Chan, K. P. Fong, Eva Y. W. Cheung, Renee W. S. Ma, Jessie S. Y. Wong, Connie N. K. Lam, Darren M. C. Poon
article en

Abstract

<b>Background</b>: Stereotactic body radiotherapy (SBRT) for prostate cancer delivers high doses in few fractions but poses challenges in sparing adjacent organs at risk (OARs), particularly the intra-prostate urethra, bladder, rectum and penile bulb. Magnetic resonance-guided radiotherapy (MRgRT) using MR-Linac offers superior soft-tissue visualization and daily adaptive planning, potentially reducing OAR dose while maintaining target coverage. This study aimed to compare dose-volume parameters among MR-Linac (ML), volumetric modulated arc therapy (VMAT), and Tomotherapy (HT) plans for prostate SBRT. <b>Methods</b>: Thirty patients with localized prostate cancer were retrospectively analyzed. For each patient, three plans were generated: ML, VMAT and HT, using identical prescription and planning objectives. Dose-volume histogram (DVH) metrics were evaluated for clinical target volume (CTV), planning target volume (PTV), and OARs. Statistical comparisons were performed using non-parametric Friedman's Test with post hoc Bonferroni test, with significance set at a <i>p</i> < 0.05. <b>Results</b>: CTV coverage was comparable across all modalities. ML achieved significantly higher PTV Dmin and near-maximum doses compared to VMAT and HT. Notably, ML provided substantial urethral sparing, reducing Dmax and Dmean by approximately 3.3 Gy compared to both VMAT and HT (<i>p</i> < 0.001). Rectal dose metrics were also lower with ML, while bladder and penile bulb doses showed minor increases (<3.5 Gy), considered clinically negligible. Femoral head doses were reduced in ML plans. <b>Conclusions</b>: MR-Linac planning for prostate SBRT offers meaningful dosimetric advantages, particularly in intra-prostate urethra urethral dose reduction, without compromising target coverage. These findings support incorporating MR-guided adaptive workflows into SBRT protocols to enhance OAR protection and potentially reduce treatment-related toxicity.

CancersVol. 18(4)
Tung Wah College (HK), Hong Kong Sanatorium and Hospital (HK), University of Hong Kong (HK)
Good health and well-being
Openalex Percentile: Top 64%
Prostate Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.