Bending behavior of concrete-filled FRP wound tubular arches with internal FRP bars

Conventional reinforced concrete arches are susceptible to corrosion in underground environments, leading to reduced durability. This study proposes concrete-filled FRP (Fiber-reinforced polymer) wound tubular arches with internal FRP bars to achieve excellent corrosion resistance. Eighteen concrete-filled FRP tubular arches were tested under mid-span concentrated loading, and the effects of FRP tube wall thickness and FRP reinforcement configuration were investigated. The experimental results demonstrate that increasing the wall thickness of the FRP tube significantly enhances the ultimate load-bearing capacity, with a maximum increase of 104.7% observed under mid-span loading. The incorporation of FRP reinforcement also resulted in 236.3%~279% increase of ultimate capacity and 111.11%-119.67% increase of displacement ductility ratio. A simplified theoretical model for predicting the ultimate load of concrete-filled FRP tubular arches with internal FRP bars was proposed, achieving a relative error within 10%. The proposed concrete-filled FRP tubular arch demonstrates considerable potential for application in underground engineering.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-09
DOI
https://doi.org/10.1038/s41598-026-38886-w
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bending behavior of concrete-filled FRP wound tubular arches with internal FRP bars

Yujun Qi, Zhenyuan Yang, Zhenglong Zhou, Guowei Wang et al.
Scientific Reports
Structural Behavior of Reinforced Concrete
article

Bending behavior of concrete-filled FRP wound tubular arches with internal FRP bars

Yujun Qi, Zhenyuan Yang, Zhenglong Zhou, Guowei Wang, Benben Li
article en

Abstract

Conventional reinforced concrete arches are susceptible to corrosion in underground environments, leading to reduced durability. This study proposes concrete-filled FRP (Fiber-reinforced polymer) wound tubular arches with internal FRP bars to achieve excellent corrosion resistance. Eighteen concrete-filled FRP tubular arches were tested under mid-span concentrated loading, and the effects of FRP tube wall thickness and FRP reinforcement configuration were investigated. The experimental results demonstrate that increasing the wall thickness of the FRP tube significantly enhances the ultimate load-bearing capacity, with a maximum increase of 104.7% observed under mid-span loading. The incorporation of FRP reinforcement also resulted in 236.3%~279% increase of ultimate capacity and 111.11%-119.67% increase of displacement ductility ratio. A simplified theoretical model for predicting the ultimate load of concrete-filled FRP tubular arches with internal FRP bars was proposed, achieving a relative error within 10%. The proposed concrete-filled FRP tubular arch demonstrates considerable potential for application in underground engineering.

Scientific ReportsVol. 16(1)
Nanjing Tech University (CN), Bengbu Medical College (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Sustainable cities and communities
Openalex Percentile: Top 61%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.