Impact of charge transfer inefficiency on transit light curves
Context . PLATO is designed to detect Earth-sized exoplanets orbiting solar-type stars and to measure their radii (relative to the star radii) with an accuracy better than 2% via the transit method. Charge transfer inefficiency (CTI), a by-product of radiation damage to charge-coupled devices (CCDs), can jeopardise this accuracy constraint and therefore must be corrected to reach scientific requirements. Aims . We assessed and quantified the impact of CTI on transit depth measurements. Our objective was to demonstrate the need for CTI correction and to develop a correction strategy that restores CTI-biased transit depths with an acceptable residual within the accuracy budget. Methods . Using a calibration dataset generated with PLATOSim to simulate a realistic stellar field, we modelled the parallel overscan signal as the sum of exponential decays and used least-squares fitting to infer the number of trap species and initial estimates for the release times ( τ r,k ). Smearing was then modelled with an exponential-plus-constant function and removed on a column-wise basis. We modelled the spatial variation in the trap density with a quadratic polynomial function of the radial distance from the centre of the focal plane. The polynomial coefficients ( a p,k ) of this model, the well-fill power index ( β ), and the release times ( τ r,k ) were subsequently adjusted via an iterative application of the extended pixel edge response method combined with a CTI correction algorithm. This yielded the final calibration model that underpins our correction strategy. Results . In the worst-case scenario (8-year mission, high CTI impact zone), we found that CTI induced a bias of approximately 4% in the measured transit depth. The polynomial coefficients from our trap density model were then used to correct the CTI-affected transit depths. Our correction reduced the bias to a residual of 0.06%, which is comfortably within PLATO’s accuracy requirements. Conclusions . We quantified the CTI-induced bias in transit depth measurements and implemented a calibration strategy that incorporates spatial variations in trap density. From the calibrated parameters, we derived a correction scheme that brought the photometric measurements within PLATO’s noise budget, ensuring that the mission’s precision requirements are met.
Authors
- R. Samadi
- D. Bérard
- S. Mishra
Institutions
- Centre National de la Recherche Scientifique (FR)
- Université Paris Cité (FR)
- Sorbonne Université (FR)
- Sorbonne Paris Cité (FR)
Publication Details
- Journal
- Astronomy and Astrophysics
- Published
- 2026-02-09
- DOI
- https://doi.org/10.1051/0004-6361/202557037
- Primary Topic
- CCD and CMOS Imaging Sensors
- Type
- article
- Field-Weighted Citation Impact
- 0.00