Optimized Dual ANN Control Technique for Efficient Energy Management System (EMS) of Microgrid

ABSTRACT The escalating global energy demand necessitates a shift towards sustainable and environmentally friendly alternatives. While renewable energy sources like solar and wind energy offer promising solutions, their intermittent nature poses significant challenges for grid integration. Microgrids, as decentralized and self‐sufficient energy systems, emerge as a viable solution by enabling the efficient integration of these renewable sources. However, effective energy management within a microgrid remains crucial to ensure optimal power flow and minimize energy losses. This paper proposes a novel optimized dual Artificial Neural Network (ANN) control strategy for a direct current (DC) microgrid. The first ANN focuses on maximizing power extraction from renewable sources by employing real‐time irradiance, temperature, and wind speed data. The second ANN intelligently controls the power flow between renewable sources, energy storage systems, the grid, and the load. Simulation results under variable load profiles for voltage, current, and power of different DC microgrid components demonstrate this approach's effectiveness in efficiently distributing power and mitigating energy losses, highlighting its potential for enhancing the reliability and sustainability of future microgrid systems. Simulation results confirmed the effectiveness of the proposed dual ANN controller, achieving a more consistent voltage and current profile, reduced energy losses, and improved power management during fluctuating load conditions. This approach demonstrated up to (insert quantitative result: for example, “20% reduction in energy losses compared with baseline EMS methods”) and maintained output stability throughout different operating scenarios.

Authors

Institutions

Publication Details

Journal
Energy Science & Engineering
Published
2026-02-09
DOI
https://doi.org/10.1002/ese3.70465
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimized Dual ANN Control Technique for Efficient Energy Management System (EMS) of Microgrid

Waseem Aslam, ABUBAKAR SIDDIQUE, Bing Qi, Hongfang Pan et al.
Energy Science & Engineering
Microgrid Control and Optimization
article

Optimized Dual ANN Control Technique for Efficient Energy Management System (EMS) of Microgrid

Waseem Aslam, ABUBAKAR SIDDIQUE, Bing Qi, Hongfang Pan, Rashid Ali, Bin Li
article en

Abstract

ABSTRACT The escalating global energy demand necessitates a shift towards sustainable and environmentally friendly alternatives. While renewable energy sources like solar and wind energy offer promising solutions, their intermittent nature poses significant challenges for grid integration. Microgrids, as decentralized and self‐sufficient energy systems, emerge as a viable solution by enabling the efficient integration of these renewable sources. However, effective energy management within a microgrid remains crucial to ensure optimal power flow and minimize energy losses. This paper proposes a novel optimized dual Artificial Neural Network (ANN) control strategy for a direct current (DC) microgrid. The first ANN focuses on maximizing power extraction from renewable sources by employing real‐time irradiance, temperature, and wind speed data. The second ANN intelligently controls the power flow between renewable sources, energy storage systems, the grid, and the load. Simulation results under variable load profiles for voltage, current, and power of different DC microgrid components demonstrate this approach's effectiveness in efficiently distributing power and mitigating energy losses, highlighting its potential for enhancing the reliability and sustainability of future microgrid systems. Simulation results confirmed the effectiveness of the proposed dual ANN controller, achieving a more consistent voltage and current profile, reduced energy losses, and improved power management during fluctuating load conditions. This approach demonstrated up to (insert quantitative result: for example, “20% reduction in energy losses compared with baseline EMS methods”) and maintained output stability throughout different operating scenarios.

Energy Science & Engineering
North China Electric Power University (CN), University of Sargodha (PK), Inner Mongolia Electric Power (China) (CN), Khwaja Fareed University of Engineering and Information Technology (PK)
Openalex Percentile: Top 62%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.