Acquisition of multi voxel size X-ray computed tomography and optical microscopy image datasets of a thermoplastic CFRP tape

Four specimens were prepared from one continuous Carbon Fiber Reinforced Thermoplastic Polymer (CFRP) tape and nondestructively tested using 2D X-ray micrographs and 3D X-ray Computed Tomography (CT). They were each polished on one front side and imaged by optical microscopy using a Keyence VK-X1000 confocal scanning microscope. These two-dimensional micrographs provided high-resolution reference data of the polished tape surfaces. CT was performed on the same specimens with a Zeiss Xradia 520 Versa at voxel sizes of 0.8, 2.0, and 3.5 µm each. The field of view was adjusted to include the polished front side, and the rotation axis was kept constant in between scans of one specimen. This configuration enabled the CT datasets to be registered into a common coordinate system. The registered stacks were subsequently cropped to the tape volume to optimize memory usage. The 3D CT datasets were segmented using structure tensor analysis and Trainable Weka Segmentation to extract fiber, matrix and pore regions in the CFRP tapes’ microstructure. The 2D microscopy images were used as complementary benchmarks to evaluate the required spatial resolution. The overall aim was to determine whether reliable microstructural characterization demands full fiber-level resolution, or whether coarser CT scans provide sufficient information.

Authors

Institutions

Publication Details

Journal
Data in Brief
Published
2026-02-09
DOI
https://doi.org/10.1016/j.dib.2026.112571
Primary Topic
Fiber-reinforced polymer composites
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Acquisition of multi voxel size X-ray computed tomography and optical microscopy image datasets of a thermoplastic CFRP tape

Clemens A. Dransfeld, Silvia Gomarasca, Christoph Queck, Martin Gurka et al.
Data in Brief
Fiber-reinforced polymer composites
article

Acquisition of multi voxel size X-ray computed tomography and optical microscopy image datasets of a thermoplastic CFRP tape

Clemens A. Dransfeld, Silvia Gomarasca, Christoph Queck, Martin Gurka, Ran Tao, Amin Hosseini, Benedikt Boos
article en

Abstract

Four specimens were prepared from one continuous Carbon Fiber Reinforced Thermoplastic Polymer (CFRP) tape and nondestructively tested using 2D X-ray micrographs and 3D X-ray Computed Tomography (CT). They were each polished on one front side and imaged by optical microscopy using a Keyence VK-X1000 confocal scanning microscope. These two-dimensional micrographs provided high-resolution reference data of the polished tape surfaces. CT was performed on the same specimens with a Zeiss Xradia 520 Versa at voxel sizes of 0.8, 2.0, and 3.5 µm each. The field of view was adjusted to include the polished front side, and the rotation axis was kept constant in between scans of one specimen. This configuration enabled the CT datasets to be registered into a common coordinate system. The registered stacks were subsequently cropped to the tape volume to optimize memory usage. The 3D CT datasets were segmented using structure tensor analysis and Trainable Weka Segmentation to extract fiber, matrix and pore regions in the CFRP tapes’ microstructure. The 2D microscopy images were used as complementary benchmarks to evaluate the required spatial resolution. The overall aim was to determine whether reliable microstructural characterization demands full fiber-level resolution, or whether coarser CT scans provide sufficient information.

Data in BriefVol. 65
Leibniz-Institut für Verbundwerkstoffe GmbH (DE), Delft University of Technology (NL)
Openalex Percentile: Top 63%
Fiber-reinforced polymer composites
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.