Thread-based colorimetric biosensor for urea determination in serum

Urea is a crucial biomarker in clinical analysis, mainly used to diagnose and monitor kidney condition. However, its reliable determination in serum in point-of-care testing format still remains a vital challenge. Here, we tackled this issue by developing a microfluidic thread-based optical biosensor for serum urea determination. The working principle of the presented device was combining enzymatic urea hydrolysis using urease with the resulting ammonium ions detection using ionophore-chromoionophore chemistry. Urease was immobilized on thread with the aid of synthesized urease-calcium phosphate nanoflowers while components for ammonium ions detection were embedded in PVC-based membrane located on the same thread. In the first step, ammonium ions determination in a thread-based sensor was optimized. Then, urease-calcium posphate nanoflowers (U-CaNFs) were included on the thread to ensure selectivity for urea. U-CaNFs synthesis was optimized and the resulting nanoflowers were characterized using various analytical techniqes (e.g. SEM, EDS, TGA, XRD). The calculated limit of detection for urea was 37 µmol L -1 and the total analysis time was only 8 min. The developed thread-based devices were validated with control sera samples, proving their high accuracy. • Thread-based colorimetric biosensor for urea determination in serum is proposed • Urease enzyme is immobilized on thread as urease-calcium phosphate nanoflowers • Ammonium ion is detected using optode membrane immobilized on thread • Limit of detection of urea is 37 µmol L -1 and total analysis time is 8 min • Thread-based devices were validated with serum samples

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2026-02-09
DOI
https://doi.org/10.1016/j.snb.2026.139644
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thread-based colorimetric biosensor for urea determination in serum

Ignacio De Orbe Payá, Miguel M. Erenas, Luis Fermín Capitán Vallvey, Paweł Bącal et al.
Sensors and Actuators B Chemical
Biosensors and Analytical Detection
article

Thread-based colorimetric biosensor for urea determination in serum

Ignacio De Orbe Payá, Miguel M. Erenas, Luis Fermín Capitán Vallvey, Paweł Bącal, Izabela Lewińska
article en

Abstract

Urea is a crucial biomarker in clinical analysis, mainly used to diagnose and monitor kidney condition. However, its reliable determination in serum in point-of-care testing format still remains a vital challenge. Here, we tackled this issue by developing a microfluidic thread-based optical biosensor for serum urea determination. The working principle of the presented device was combining enzymatic urea hydrolysis using urease with the resulting ammonium ions detection using ionophore-chromoionophore chemistry. Urease was immobilized on thread with the aid of synthesized urease-calcium phosphate nanoflowers while components for ammonium ions detection were embedded in PVC-based membrane located on the same thread. In the first step, ammonium ions determination in a thread-based sensor was optimized. Then, urease-calcium posphate nanoflowers (U-CaNFs) were included on the thread to ensure selectivity for urea. U-CaNFs synthesis was optimized and the resulting nanoflowers were characterized using various analytical techniqes (e.g. SEM, EDS, TGA, XRD). The calculated limit of detection for urea was 37 µmol L -1 and the total analysis time was only 8 min. The developed thread-based devices were validated with control sera samples, proving their high accuracy. • Thread-based colorimetric biosensor for urea determination in serum is proposed • Urease enzyme is immobilized on thread as urease-calcium phosphate nanoflowers • Ammonium ion is detected using optode membrane immobilized on thread • Limit of detection of urea is 37 µmol L -1 and total analysis time is 8 min • Thread-based devices were validated with serum samples

Sensors and Actuators B ChemicalVol. 455
Universidad de Granada (ES), Institute of Paleobiology (PL), University of Warsaw (PL), Polish Academy of Sciences (PL)
Fundacja na rzecz Nauki Polskiej, Universidad de Granada, Junta de Andalucía, European Regional Development Fund, Agencia Estatal de Investigación
Openalex Percentile: Top 63%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.