Millimeter-Wave Radar-Based Weak Neonatal Heart Rate Detection Using an Adaptive Subband Variable Step-Size LMS Filtering Algorithm

Non-contact measurement plays a crucial role in monitoring the heart rate of preterm and low birth weight infants in the neonatal intensive care unit (NICU). Addressing the challenges of weak heartbeat signals easily overwhelmed by noise in non-contact heart rate detection for these neonates, this paper proposes a millimeter-wave radar-based heart rate detection method using adaptive subband variable step-size least mean square (LMS) filtering. The innovative approach divides the chest echo signal into multiple subbands, employing an error-based variable step-size update strategy in each subband. By utilizing the abdominal signal as a reference, the heartbeat information is enhanced through adaptive filtering, and the results from various subbands are fused. The heart rate estimation is achieved by combining the fused results with time-frequency analysis using wavelet transform. Experimental results on data collected from multiple preterm infants in the NICU demonstrate that the proposed algorithm can reduce the root mean square error (RMSE) of preterm infant heart rate estimation to below 5 Beats Per Minute (BPM), providing a novel solution for the application of millimeter-wave radar in NICU heart rate monitoring.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-02-09
DOI
https://doi.org/10.3390/electronics15040731
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Millimeter-Wave Radar-Based Weak Neonatal Heart Rate Detection Using an Adaptive Subband Variable Step-Size LMS Filtering Algorithm

Xiangwei Dang, Yong Li, Junyi Cao, Nanyi Jiang et al.
Electronics
Non-Invasive Vital Sign Monitoring
article

Millimeter-Wave Radar-Based Weak Neonatal Heart Rate Detection Using an Adaptive Subband Variable Step-Size LMS Filtering Algorithm

Xiangwei Dang, Yong Li, Junyi Cao, Nanyi Jiang, Xiao Li
article en

Abstract

Non-contact measurement plays a crucial role in monitoring the heart rate of preterm and low birth weight infants in the neonatal intensive care unit (NICU). Addressing the challenges of weak heartbeat signals easily overwhelmed by noise in non-contact heart rate detection for these neonates, this paper proposes a millimeter-wave radar-based heart rate detection method using adaptive subband variable step-size least mean square (LMS) filtering. The innovative approach divides the chest echo signal into multiple subbands, employing an error-based variable step-size update strategy in each subband. By utilizing the abdominal signal as a reference, the heartbeat information is enhanced through adaptive filtering, and the results from various subbands are fused. The heart rate estimation is achieved by combining the fused results with time-frequency analysis using wavelet transform. Experimental results on data collected from multiple preterm infants in the NICU demonstrate that the proposed algorithm can reduce the root mean square error (RMSE) of preterm infant heart rate estimation to below 5 Beats Per Minute (BPM), providing a novel solution for the application of millimeter-wave radar in NICU heart rate monitoring.

ElectronicsVol. 15(4)
North China University of Technology (CN), Chinese Academy of Sciences (CN), Peking University (CN), Aerospace Information Research Institute (CN), Peking University Third Hospital (CN), University of Chinese Academy of Sciences (CN)
Good health and well-being
Openalex Percentile: Top 63%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Millimeter-Wave Radar-Based Weak Neonatal Heart Rate Detection Using an Adaptive Subband Variable Step-Size LMS Filtering Algorithm — Xiangwei Dang, Yong Li, et al. · Electronics (2026) | TGRS Research Map | TGRS