Motion-robust myelin imaging in MRI using 1D projection gating

Myelin-weighted imaging with inversion-recovery ultrashort-echo-time (IR-UTE) is highly motion-sensitive, yet extra hardware or longer scans are impractical. We evaluated whether a 1D superior–inferior (SI) navigator with bit-reversed spoke-angles mitigates motion artifacts without extending acquisition. Dual-echo IR-UTE was implemented at 3T. After an adiabatic inversion pulse, 21 spokes were acquired per segment around the white-matter null point, and dual-echo subtraction suppressed residual long-T2 signals. Adding SI-navigators at the end of each segment allows motion detection without lengthening TR. And bit-reversal is used to pseudo-randomize the spoke-angles. Bloch simulations of a 2D synthetic brain removed 10% of spokes to mimic gating. Three volunteers were scanned: (i) sequential-ordering, no-motion; (ii) bit-reversed, no-motion; (iii) bit-reversed with deliberate head nods. The navigator rejected 1,280 of 12,000 spokes (10.7%) during nodding, and the same gating was reconstructed on motion-free data. Simulation showed coherent streaks for sequential ordering but an isotropic point-spread function for bit-reversal. In vivo, gating degraded only the sequential dataset. bit-reversal preserved subcortical and deep-white-matter detail. During intentional nodding, gating with bit-reversal enhanced myelin contrast, outperforming the image reconstructed from the ungated data. The SI-navigator plus bit-reversal enables effective motion gating without hardware or time penalty, supporting routine motion-robust myelin mapping.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-02-09
DOI
https://doi.org/10.1038/s41598-026-39238-4
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Motion-robust myelin imaging in MRI using 1D projection gating

Eddie Fu, Nian Wang, Jinil Park, Kader Karli Oguz et al.
Scientific Reports
Advanced MRI Techniques and Applications
article

Motion-robust myelin imaging in MRI using 1D projection gating

Eddie Fu, Nian Wang, Jinil Park, Kader Karli Oguz, Youngkyoo Jung, Sam Sedaghat, Fang Liu, Hyungseok Jang
article en

Abstract

Myelin-weighted imaging with inversion-recovery ultrashort-echo-time (IR-UTE) is highly motion-sensitive, yet extra hardware or longer scans are impractical. We evaluated whether a 1D superior–inferior (SI) navigator with bit-reversed spoke-angles mitigates motion artifacts without extending acquisition. Dual-echo IR-UTE was implemented at 3T. After an adiabatic inversion pulse, 21 spokes were acquired per segment around the white-matter null point, and dual-echo subtraction suppressed residual long-T2 signals. Adding SI-navigators at the end of each segment allows motion detection without lengthening TR. And bit-reversal is used to pseudo-randomize the spoke-angles. Bloch simulations of a 2D synthetic brain removed 10% of spokes to mimic gating. Three volunteers were scanned: (i) sequential-ordering, no-motion; (ii) bit-reversed, no-motion; (iii) bit-reversed with deliberate head nods. The navigator rejected 1,280 of 12,000 spokes (10.7%) during nodding, and the same gating was reconstructed on motion-free data. Simulation showed coherent streaks for sequential ordering but an isotropic point-spread function for bit-reversal. In vivo, gating degraded only the sequential dataset. bit-reversal preserved subcortical and deep-white-matter detail. During intentional nodding, gating with bit-reversal enhanced myelin contrast, outperforming the image reconstructed from the ungated data. The SI-navigator plus bit-reversal enables effective motion gating without hardware or time penalty, supporting routine motion-robust myelin mapping.

Scientific ReportsVol. 16(1)
Harvard University (US), Heidelberg University (DE), University Hospital Heidelberg (DE), University of California System (US), Massachusetts General Hospital (US), Southwestern Medical Center (US), Athinoula A. Martinos Center for Biomedical Imaging (US), Advanced Imaging Research (United States) (US), University of California, Davis (US), The University of Texas Southwestern Medical Center (US)
Openalex Percentile: Top 63%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.