Study of the effect of the microfluidic effect on reducing the reaction times

This study investigated the possibility of generating cavitation effects in microfluidic reactors at sharp pressure drops (from 10 to 1 atm.) without the use of ultrasonic sources. The calculations revealed that with the parameters characteristic of microfluidic systems (channel diameter of 1 mm, flow rate of 100 ml/h), an energy dissipation rate of approximately 3.225 W/cm² was achieved. This value exceeds the known cavitation threshold for aqueous solutions and is within the interval characteristic of cavitation induced by high-frequency sources. A decrease in the diameter of the channel contributes to an increase in specific power, thereby increasing the probability of cavitation. The dependencies of the kinetics of the first-order reaction on the intensity of cavitation were determined. At α = 0.8 (cavitation amplification coefficient selected from the literature), the velocity constant increases from 0.010 to 0.0358 s–1, which leads to a significant reduction in the time required to achieve a given degree of transformation.

Authors

Publication Details

Journal
Springer Link (Chiba Institute of Technology)
Published
2026-02-05
DOI
https://doi.org/10.1051/epjconf/202635101015/pdf
Primary Topic
Ultrasound and Cavitation Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of the effect of the microfluidic effect on reducing the reaction times

Shishanov Mikhail Valentinovich, Cook Christopher German
Springer Link (Chiba Institute of Technology)
Ultrasound and Cavitation Phenomena
article

Study of the effect of the microfluidic effect on reducing the reaction times

Shishanov Mikhail Valentinovich, Cook Christopher German
article en

Abstract

This study investigated the possibility of generating cavitation effects in microfluidic reactors at sharp pressure drops (from 10 to 1 atm.) without the use of ultrasonic sources. The calculations revealed that with the parameters characteristic of microfluidic systems (channel diameter of 1 mm, flow rate of 100 ml/h), an energy dissipation rate of approximately 3.225 W/cm² was achieved. This value exceeds the known cavitation threshold for aqueous solutions and is within the interval characteristic of cavitation induced by high-frequency sources. A decrease in the diameter of the channel contributes to an increase in specific power, thereby increasing the probability of cavitation. The dependencies of the kinetics of the first-order reaction on the intensity of cavitation were determined. At α = 0.8 (cavitation amplification coefficient selected from the literature), the velocity constant increases from 0.010 to 0.0358 s–1, which leads to a significant reduction in the time required to achieve a given degree of transformation.

Springer Link (Chiba Institute of Technology)
Affordable and clean energy
Openalex Percentile: Top 63%
Ultrasound and Cavitation Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study of the effect of the microfluidic effect on reducing the reaction times — Shishanov Mikhail Valentinovich, Cook Christopher German · Springer Link (Chiba Institute of Technology) (2026) | TGRS Research Map | TGRS