Monitoring Hemoglobin Oxygenation Using the NIRS4 Device and the Developed Algorithm

Wearable devices that continuously monitor the body’s physiological signals make it possible to diagnose and treat diseases, as well as improve the effectiveness of physical activity. When measuring quantitative parameters using near-infrared (IR) spectroscopy, a problem arises related to indefiniteness of the optical length of the optical pathway. Without knowing optical length, it is impossible to obtain precise values; hence, the quantitative indicators will be the relative concentrations of hemoglobin in terms of relative units. In this study, a comparative assessment and analysis of the results of measuring hemoglobin oxygenation using the NIRS4 device and the developed algorithm are conducted. The experiments conducted to determine the oxygenation index are described. It is found that the measured values for each hemoglobin fraction correspond to known values, and the calculation of the oxygenated hemoglobin concentration using the developed method gives changes in the concentration of the same order as the typical data for other methods and devices. The results of the study can be used for early diagnosis of the biochemical activity of the body. This presents new opportunities for the development of methods for diagnosing and monitoring a person’s health status based on indicators of the hemoglobin concentration in the blood.

Authors

Institutions

Publication Details

Journal
Russian Microelectronics
Published
2025-12-01
DOI
https://doi.org/10.1134/s1063739725700180
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Monitoring Hemoglobin Oxygenation Using the NIRS4 Device and the Developed Algorithm

P. V. Shalaev, A. Yu. Gerasimenko, P. A. Monakhova, D. A. Buyanov
Russian Microelectronics
Optical Imaging and Spectroscopy Techniques
article

Monitoring Hemoglobin Oxygenation Using the NIRS4 Device and the Developed Algorithm

P. V. Shalaev, A. Yu. Gerasimenko, P. A. Monakhova, D. A. Buyanov
article en

Abstract

Wearable devices that continuously monitor the body’s physiological signals make it possible to diagnose and treat diseases, as well as improve the effectiveness of physical activity. When measuring quantitative parameters using near-infrared (IR) spectroscopy, a problem arises related to indefiniteness of the optical length of the optical pathway. Without knowing optical length, it is impossible to obtain precise values; hence, the quantitative indicators will be the relative concentrations of hemoglobin in terms of relative units. In this study, a comparative assessment and analysis of the results of measuring hemoglobin oxygenation using the NIRS4 device and the developed algorithm are conducted. The experiments conducted to determine the oxygenation index are described. It is found that the measured values for each hemoglobin fraction correspond to known values, and the calculation of the oxygenated hemoglobin concentration using the developed method gives changes in the concentration of the same order as the typical data for other methods and devices. The results of the study can be used for early diagnosis of the biochemical activity of the body. This presents new opportunities for the development of methods for diagnosing and monitoring a person’s health status based on indicators of the hemoglobin concentration in the blood.

Russian MicroelectronicsVol. 54(7)
Sechenov University (RU), National Research University of Electronic Technology (RU), InSysBio (Russia) (RU), Aivok (Russia) (RU)
Good health and well-being
Openalex Percentile: Top 27%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.