Thermal Lens Vibrational Overtone Spectroscopy for Detection of Impurities in Liquid Alkanes

In this investigation, the local mode model for C-H overtone transitions in hydrocarbons and the thermal lens (TL) technique are used to obtain vibrational overtone spectra and subsequent analysis of hydrocarbon impurities in liquid solutions. The experimental thermal lens design enables the detection of hydrocarbon solutes in trace amounts within a hydrocarbon solvent by exciting two distinct vibrational overtones. To exemplify the method, we present the thermal lens signal corresponding to the (Δυ = 6) overtone of benzene or naphthalene as impurities in solvents such as n-hexane or iso-octane. The lowest composition recorded for benzene in n-hexane was 0.005%, while for naphthalene in n-hexane it was 0.001%. Additionally, we explore more sensitive experiments where the (Δυ = 5) transition of the impurity is detected concurrently with the (Δυ = 6) transition of the solvent. This analytical method can also be adapted for use with saturated alcohols in solution contaminating hydrocarbon solvents.

Authors

Institutions

Publication Details

Journal
Chemosensors
Published
2026-02-09
DOI
https://doi.org/10.3390/chemosensors14020047
Primary Topic
Thermography and Photoacoustic Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Lens Vibrational Overtone Spectroscopy for Detection of Impurities in Liquid Alkanes

Carlos E. Manzanares, Parashu R. Nyaupane, David Camejo, Miguel Rodriguez-Escalante et al.
Chemosensors
Thermography and Photoacoustic Techniques
article

Thermal Lens Vibrational Overtone Spectroscopy for Detection of Impurities in Liquid Alkanes

Carlos E. Manzanares, Parashu R. Nyaupane, David Camejo, Miguel Rodriguez-Escalante, Helena Diez-y-Riega
article en

Abstract

In this investigation, the local mode model for C-H overtone transitions in hydrocarbons and the thermal lens (TL) technique are used to obtain vibrational overtone spectra and subsequent analysis of hydrocarbon impurities in liquid solutions. The experimental thermal lens design enables the detection of hydrocarbon solutes in trace amounts within a hydrocarbon solvent by exciting two distinct vibrational overtones. To exemplify the method, we present the thermal lens signal corresponding to the (Δυ = 6) overtone of benzene or naphthalene as impurities in solvents such as n-hexane or iso-octane. The lowest composition recorded for benzene in n-hexane was 0.005%, while for naphthalene in n-hexane it was 0.001%. Additionally, we explore more sensitive experiments where the (Δυ = 5) transition of the impurity is detected concurrently with the (Δυ = 6) transition of the solvent. This analytical method can also be adapted for use with saturated alcohols in solution contaminating hydrocarbon solvents.

ChemosensorsVol. 14(2)
Baylor University (US), Lone Star College (US)
Baylor University
Openalex Percentile: Top 62%
Thermography and Photoacoustic Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.