Analysis of Screwed Electrical Connections for HTS Tapes

A demountable connection is necessary to enable quick and easy replacement of high-temperature superconducting (HTS) tape samples during cryogenic (77 K) testing, particularly when investigating their application in superconducting fault current limiters (SFCLs). Testing HTS tapes for application in SFCLs involves inducing their transition from the superconducting state to the resistive state, which can result in sample damage. The contact resistance of the HTS tape to the current lead depends on the area and on the uniform pressure. Stress distribution in screwed connections with two, four and six screws was analysed using a solid model to compare them and achieve the uniform contact essential for minimising contact resistance in cryogenic conditions. The analysis indicated a solution that provides the most uniform pressure distribution across the HTS tape surface. This solution was utilised in subsequent calculations of thermal shrinkage, and for the determination of the optimal disc spring stack configuration. It is imperative that the compensating disc springs maintain the requisite pressure of the copper block on the tape across the entire operational temperature range (room to cryogenic). Furthermore, the disc springs must provide adequate stroke to compensate for the thermal shrinkage of a copper block and an aluminium clamp.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-02-09
DOI
https://doi.org/10.3390/en19040889
Primary Topic
Physics of Superconductivity and Magnetism
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Screwed Electrical Connections for HTS Tapes

J. Kozak
Energies
Physics of Superconductivity and Magnetism
article

Analysis of Screwed Electrical Connections for HTS Tapes

J. Kozak
article en

Abstract

A demountable connection is necessary to enable quick and easy replacement of high-temperature superconducting (HTS) tape samples during cryogenic (77 K) testing, particularly when investigating their application in superconducting fault current limiters (SFCLs). Testing HTS tapes for application in SFCLs involves inducing their transition from the superconducting state to the resistive state, which can result in sample damage. The contact resistance of the HTS tape to the current lead depends on the area and on the uniform pressure. Stress distribution in screwed connections with two, four and six screws was analysed using a solid model to compare them and achieve the uniform contact essential for minimising contact resistance in cryogenic conditions. The analysis indicated a solution that provides the most uniform pressure distribution across the HTS tape surface. This solution was utilised in subsequent calculations of thermal shrinkage, and for the determination of the optimal disc spring stack configuration. It is imperative that the compensating disc springs maintain the requisite pressure of the copper block on the tape across the entire operational temperature range (room to cryogenic). Furthermore, the disc springs must provide adequate stroke to compensate for the thermal shrinkage of a copper block and an aluminium clamp.

EnergiesVol. 19(4)
Lublin University of Technology (PL)
Openalex Percentile: Top 61%
Physics of Superconductivity and Magnetism
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.