Incorporating Cu(II) to Biodegradable Mg Surface via Schiff Base Covalently Grafted UiO‐66‐NH <sub>2</sub> Coating for Synergistic Integration of Corrosion Control and Biofunctionalization

Magnesium (Mg)-based implant materials exhibit unique biodegradable properties, but their excessively rapid corrosion leads to compromised mechanical performance, reduced biocompatibility, and insufficient capability to meet multifarious clinical demands. Herein, this work developed a multifunctional coating that both addresses corrosion protection and enables multifunctional applications. A facile Cu(II)-incorporated coating system through Schiff base covalently grafted UiO-66-NH<sub>2</sub> is constructed onto Mg surface for synergistic integration of corrosion control and biofunctionalization. The Cu(II) active sites contribute to biocatalytic reactions and antibacterial action, which can catalyze the decomposition of S-nitrosoglutathione (GSNO) to release NO (1.7 × 10<sup>-7</sup> mol cm<sup>-2</sup> min<sup>-1</sup>) for vasodilation, effectively decompose H<sub>2</sub>O<sub>2</sub>, and scavenge reactive oxygen species (ROS) to alleviate oxidative stress (catalytic decomposition and removal efficiency exceed 60%), as well as demonstrate superior antibacterial efficacy against both E. coli and S. aureus (over 99.9% inhibition rates). Moreover, the coating remarkably retards Mg corrosion and significantly improves cytocompatibility and hemocompatibility of Mg surface. Simultaneous control of Cu<sup>2+</sup> and Mg<sup>2+</sup> ions release on the surface microenvironment facilitates biochemical effect on osteoblast differentiation ability (gene expression of RUNX2 + 356% and OCN + 223%). This work opens up a feasible route of developing a multipurpose surface modification strategy incorporating metal active sites to Mg surface for customized functions.

Authors

Institutions

Publication Details

Journal
ChemSusChem
Published
2026-02-01
DOI
https://doi.org/10.1002/cssc.202501770
Primary Topic
Magnesium Alloys: Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Incorporating Cu(II) to Biodegradable Mg Surface via Schiff Base Covalently Grafted UiO‐66‐NH 2 Coating for Synergistic Integration of Corrosion Control and Biofunctionalization

Kai Qi, Yuchu Tao, Xingpeng Guo, Yubing Qiu et al.
ChemSusChem
Magnesium Alloys: Properties and Applications
article

Incorporating Cu(II) to Biodegradable Mg Surface via Schiff Base Covalently Grafted UiO‐66‐NH 2 Coating for Synergistic Integration of Corrosion Control and Biofunctionalization

Kai Qi, Yuchu Tao, Xingpeng Guo, Yubing Qiu, Chan Xue
article en

Abstract

Magnesium (Mg)-based implant materials exhibit unique biodegradable properties, but their excessively rapid corrosion leads to compromised mechanical performance, reduced biocompatibility, and insufficient capability to meet multifarious clinical demands. Herein, this work developed a multifunctional coating that both addresses corrosion protection and enables multifunctional applications. A facile Cu(II)-incorporated coating system through Schiff base covalently grafted UiO-66-NH<sub>2</sub> is constructed onto Mg surface for synergistic integration of corrosion control and biofunctionalization. The Cu(II) active sites contribute to biocatalytic reactions and antibacterial action, which can catalyze the decomposition of S-nitrosoglutathione (GSNO) to release NO (1.7 × 10<sup>-7</sup> mol cm<sup>-2</sup> min<sup>-1</sup>) for vasodilation, effectively decompose H<sub>2</sub>O<sub>2</sub>, and scavenge reactive oxygen species (ROS) to alleviate oxidative stress (catalytic decomposition and removal efficiency exceed 60%), as well as demonstrate superior antibacterial efficacy against both E. coli and S. aureus (over 99.9% inhibition rates). Moreover, the coating remarkably retards Mg corrosion and significantly improves cytocompatibility and hemocompatibility of Mg surface. Simultaneous control of Cu<sup>2+</sup> and Mg<sup>2+</sup> ions release on the surface microenvironment facilitates biochemical effect on osteoblast differentiation ability (gene expression of RUNX2 + 356% and OCN + 223%). This work opens up a feasible route of developing a multipurpose surface modification strategy incorporating metal active sites to Mg surface for customized functions.

ChemSusChemVol. 19(3)
Medical Protective (US), Guangzhou University (CN)
Openalex Percentile: Top 64%
Magnesium Alloys: Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.