Comparative study of exergy and grey relational analyses for cascade and single counterflow Ranque-Hilsch vortex tubes
Abstract In this study, the exergy analysis and second law efficiency of two separate experimental vortex tubes, one single and the other cascade-connected, were calculated and evaluated independently. This experimental study was conducted for the first time in the literature to validate the hypothesis that a cascade-connected vortex tube would exhibit superior second-law efficiency and lower exergy losses compared to a single vortex tube. Air was used as the pressurized fluid in the vortex tubes of the experimental systems. Moreover, grey relational analysis was utilized to analyze complex multi-response systems. Based on the results, a comparison of the exergy analyses for the cascade counterflow vortex tube and the single counterflow vortex tube revealed that, at a pressure of 650 kPa, the cascade counterflow Ranque-Hilsch vortex tube (CRHVT) with five brass nozzles exhibited an exergy loss of 44.57 kJkg −1 . Additionally, the CRHVT with five brass nozzles achieved the highest second law efficiency among the two systems, approximately 71%, at the same pressure. The findings from the grey relational analysis further demonstrated that the cascade counterflow vortex tube with five brass nozzles exhibited the best system performance. At a pressure of 650 kPa, the second law efficiency of this configuration was approximately 10% higher than that of the single counterflow Ranque-Hilsch vortex tube (SRHVT) under identical experimental conditions.
Authors
- Murat Korkmaz (ORCID: https://orcid.org/0000-0002-3721-2854)
Institutions
- Hacettepe University (TR)
Publication Details
- Journal
- Journal of Thermal Analysis and Calorimetry
- Published
- 2026-02-01
- DOI
- https://doi.org/10.1007/s10973-025-15223-3
- Primary Topic
- Ranque-Hilsch vortex tube
- Type
- article
- Field-Weighted Citation Impact
- 0.00