Long-Lived Phosphorescent CDs@SiO <sub>2</sub> Coupled with Magnetic Quencher Fe <sub>3</sub> O <sub>4</sub> @PDA: A Dual-Mode Lateral Flow Immunochromatographic Assay for Sensitive Determination of Acetamiprid

Lateral flow immunochromatographic assay (LFIA) features advantages such as a rapid analysis process, interpretable detection results, and low cost, making it an effective method for on-site detection of pesticides. However, the existing LFIA technologies still face bottleneck issues, including strong background fluorescence interference from the substrate and insufficient detection sensitivity for low pesticide residue levels. Here, long-lived room-temperature phosphorescent carbon dots embedded in silica (CDs@SiO<sub>2</sub>) were developed to overcome background fluorescence interference. Fe<sub>3</sub>O<sub>4</sub> coated with dopamine (Fe<sub>3</sub>O<sub>4</sub>@PDA) was utilized for the enrichment of target pesticide molecules. Meanwhile, by virtue of the quenching effect of Fe<sub>3</sub>O<sub>4</sub>@PDA on CDs@SiO<sub>2</sub>, colorimetric and phosphorescent dual-mode LFIA technology was designed for the detection of the pesticide acetamiprid. Through the integration of the advantages of CDs@SiO<sub>2</sub> and Fe<sub>3</sub>O<sub>4</sub>@PDA, the limit of detection (LOD) for acetamiprid was as low as 0.271 ng/mL, and satisfactory recoveries were achieved in real samples. This research breaks through the millisecond-level lifetime limitation in traditional time-resolved fluorescence immunoassays, providing novel insight for the development of labeling materials for LFIA.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2026-02-05
DOI
https://doi.org/10.1021/acs.analchem.5c07389
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Long-Lived Phosphorescent CDs@SiO 2 Coupled with Magnetic Quencher Fe 3 O 4 @PDA: A Dual-Mode Lateral Flow Immunochromatographic Assay for Sensitive Determination of Acetamiprid

Qianqian Jiang, Hao Shen, R H Chen, Zongjun Zhang et al.
Analytical Chemistry
Biosensors and Analytical Detection
article

Long-Lived Phosphorescent CDs@SiO 2 Coupled with Magnetic Quencher Fe 3 O 4 @PDA: A Dual-Mode Lateral Flow Immunochromatographic Assay for Sensitive Determination of Acetamiprid

Qianqian Jiang, Hao Shen, R H Chen, Zongjun Zhang, Cheng Zhang, Tong Zhang, Kui Zhang
article en

Abstract

Lateral flow immunochromatographic assay (LFIA) features advantages such as a rapid analysis process, interpretable detection results, and low cost, making it an effective method for on-site detection of pesticides. However, the existing LFIA technologies still face bottleneck issues, including strong background fluorescence interference from the substrate and insufficient detection sensitivity for low pesticide residue levels. Here, long-lived room-temperature phosphorescent carbon dots embedded in silica (CDs@SiO<sub>2</sub>) were developed to overcome background fluorescence interference. Fe<sub>3</sub>O<sub>4</sub> coated with dopamine (Fe<sub>3</sub>O<sub>4</sub>@PDA) was utilized for the enrichment of target pesticide molecules. Meanwhile, by virtue of the quenching effect of Fe<sub>3</sub>O<sub>4</sub>@PDA on CDs@SiO<sub>2</sub>, colorimetric and phosphorescent dual-mode LFIA technology was designed for the detection of the pesticide acetamiprid. Through the integration of the advantages of CDs@SiO<sub>2</sub> and Fe<sub>3</sub>O<sub>4</sub>@PDA, the limit of detection (LOD) for acetamiprid was as low as 0.271 ng/mL, and satisfactory recoveries were achieved in real samples. This research breaks through the millisecond-level lifetime limitation in traditional time-resolved fluorescence immunoassays, providing novel insight for the development of labeling materials for LFIA.

Analytical ChemistryVol. 98(6)
Anhui University (CN), Integrated Optoelectronics (Norway) (NO), Anhui University of Technology (CN), Xinjiang University (CN)
Openalex Percentile: Top 65%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Long-Lived Phosphorescent CDs@SiO <sub>2</sub> Coupled with Magnetic Quencher Fe <sub>3</sub> O <sub>4</sub> @PDA: A Dual-Mode Lateral Flow Immunochromatographic Assay for Sensitive Determination of Acetamiprid — Qianqian Jiang, Hao Shen, et al. · Analytical Chemistry (2026) | TGRS Research Map | TGRS