Quantitative assessment of PV modules affected by Type-C cracks using electroluminescence imaging

Cracks in photovoltaic modules are among the defects that can lead to the highest power losses. While the qualitative analysis of such failures has been widely studied, quantitative assessments remain relatively scarce. Accurately estimating the power loss associated with these defects is therefore essential to assess module performance, guide decision-making in maintenance activities and ensure long-term photovoltaic system performance. This paper presents the application of a methodology to quantify Type-C crack severity across the cells of a sample of 100 photovoltaic modules from two different manufacturers that have been in operation for 11 years. The methodology combines automatic crack segmentation of electroluminescence images with a quantitative assessment of the power losses associated with Type-C cracks. The statistical analysis of the sample indicates that the best probability distribution fitting the power loss estimation results is the Generalized Extreme Value distribution, with a mean value of 12.77%. This suggests a slightly higher average power loss than expected according to the acceptance/rejection criteria established, reflecting that the sample exhibits slight degradation while remaining operational. Furthermore, the shape of the resulting distribution suggests that it is unlikely to observe modules exceeding the 20% of power loss. The approach used to estimate power loss highlights the importance of detecting the distribution of cracks across the photovoltaic module, as concentrated Type-C cracks in a cell can lead to significant power losses for the module. The proposed approach enables proactive maintenance by identifying severely cracked modules for replacement, improving plant performance.

Authors

Institutions

Publication Details

Journal
Solar Energy
Published
2026-02-05
DOI
https://doi.org/10.1016/j.solener.2026.114394
Citations
1
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
9.79
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative assessment of PV modules affected by Type-C cracks using electroluminescence imaging

Germán Álvarez-Tey, Rafael Jiménez-Castañeda, N. Saborido-Barba, Carmen García-López et al.
1 citations
Solar Energy
Photovoltaic System Optimization Techniques
9.79
article

Quantitative assessment of PV modules affected by Type-C cracks using electroluminescence imaging

Germán Álvarez-Tey, Rafael Jiménez-Castañeda, N. Saborido-Barba, Carmen García-López, Ibrahim Cletus-Swilla, J.A. Clavijo-Blanco
article en
1 citations

Abstract

Cracks in photovoltaic modules are among the defects that can lead to the highest power losses. While the qualitative analysis of such failures has been widely studied, quantitative assessments remain relatively scarce. Accurately estimating the power loss associated with these defects is therefore essential to assess module performance, guide decision-making in maintenance activities and ensure long-term photovoltaic system performance. This paper presents the application of a methodology to quantify Type-C crack severity across the cells of a sample of 100 photovoltaic modules from two different manufacturers that have been in operation for 11 years. The methodology combines automatic crack segmentation of electroluminescence images with a quantitative assessment of the power losses associated with Type-C cracks. The statistical analysis of the sample indicates that the best probability distribution fitting the power loss estimation results is the Generalized Extreme Value distribution, with a mean value of 12.77%. This suggests a slightly higher average power loss than expected according to the acceptance/rejection criteria established, reflecting that the sample exhibits slight degradation while remaining operational. Furthermore, the shape of the resulting distribution suggests that it is unlikely to observe modules exceeding the 20% of power loss. The approach used to estimate power loss highlights the importance of detecting the distribution of cracks across the photovoltaic module, as concentrated Type-C cracks in a cell can lead to significant power losses for the module. The proposed approach enables proactive maintenance by identifying severely cracked modules for replacement, improving plant performance.

Solar EnergyVol. 308
The University of Dodoma (TZ), Universidad de Cádiz (ES)
Openalex Percentile: Top 3%
Photovoltaic System Optimization Techniques
9.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.