Managing Primary Immunodeficiency Immunoglobulin Replacement Therapy‐Related Adverse Events With Recombinant Human <scp>C1</scp> Esterase Inhibitor Prophylaxis: A Case Report

Immunoglobulin replacement therapy (IRT) for primary immunodeficiency reduces infection risk and subsequent complications and can be lifesaving. However, IRT can cause severe systemic adverse events (AEs) that may limit adequate dosing. These AEs may be caused, in part, by activation and/or consumption of complement proteins, thereby lowering C1 esterase inhibitor (C1-INH) levels. Data suggest that C1-INH administration prior to intravenous immunoglobulin (IVIG) may reduce IVIG-related AEs. This case describes an adult with common variable immunodeficiency unable to tolerate IRT therapy (subcutaneous immunoglobulin [SCIG] 20% solution once weekly). She experienced AEs of severe neuropathy, described as burning and pins-and-needles sensation in the extremities and muscle twitching for several days post-treatment. Dose decreases of SCIG to 0.5 g did not improve the AE profile. Inability to tolerate IRT caused suboptimal dosing and inadequate primary immunodeficiency management, resulting in hospitalizations for pneumonia and sepsis. A trial of recombinant human C1-INH 4200 U was administered intravenously over approximately 5 min, 1 h prior to SCIG 1 g (Day 1). This dose was well tolerated with minimal AEs reported. SCIG 3 g was administered on Days 2 and 3 with no AEs reported. By continuing routine recombinant human C1-INH 4200 U prophylaxis, the patient was able to tolerate the recommended dose of SCIG 20 g once weekly without the debilitating neuropathy and other AEs previously experienced with SCIG alone. This case suggests that a patient with IRT-related AEs may benefit from C1-INH replacement therapy prior to SCIG/IVIG administration to improve tolerability.

Authors

Institutions

Publication Details

Journal
Clinical Case Reports
Published
2026-02-01
DOI
https://doi.org/10.1002/ccr3.71988
Primary Topic
Immunodeficiency and Autoimmune Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Managing Primary Immunodeficiency Immunoglobulin Replacement Therapy‐Related Adverse Events With Recombinant Human C1 Esterase Inhibitor Prophylaxis: A Case Report

Douglas H. Jones, Heidi Memmott
Clinical Case Reports
Immunodeficiency and Autoimmune Disorders
article

Managing Primary Immunodeficiency Immunoglobulin Replacement Therapy‐Related Adverse Events With Recombinant Human C1 Esterase Inhibitor Prophylaxis: A Case Report

Douglas H. Jones, Heidi Memmott
article en

Abstract

Immunoglobulin replacement therapy (IRT) for primary immunodeficiency reduces infection risk and subsequent complications and can be lifesaving. However, IRT can cause severe systemic adverse events (AEs) that may limit adequate dosing. These AEs may be caused, in part, by activation and/or consumption of complement proteins, thereby lowering C1 esterase inhibitor (C1-INH) levels. Data suggest that C1-INH administration prior to intravenous immunoglobulin (IVIG) may reduce IVIG-related AEs. This case describes an adult with common variable immunodeficiency unable to tolerate IRT therapy (subcutaneous immunoglobulin [SCIG] 20% solution once weekly). She experienced AEs of severe neuropathy, described as burning and pins-and-needles sensation in the extremities and muscle twitching for several days post-treatment. Dose decreases of SCIG to 0.5 g did not improve the AE profile. Inability to tolerate IRT caused suboptimal dosing and inadequate primary immunodeficiency management, resulting in hospitalizations for pneumonia and sepsis. A trial of recombinant human C1-INH 4200 U was administered intravenously over approximately 5 min, 1 h prior to SCIG 1 g (Day 1). This dose was well tolerated with minimal AEs reported. SCIG 3 g was administered on Days 2 and 3 with no AEs reported. By continuing routine recombinant human C1-INH 4200 U prophylaxis, the patient was able to tolerate the recommended dose of SCIG 20 g once weekly without the debilitating neuropathy and other AEs previously experienced with SCIG alone. This case suggests that a patient with IRT-related AEs may benefit from C1-INH replacement therapy prior to SCIG/IVIG administration to improve tolerability.

Clinical Case ReportsVol. 14(2)
BJC HealthCare (US), Rocky Mountain Multiple Sclerosis Clinic (US)
Good health and well-being
Openalex Percentile: Top 64%
Immunodeficiency and Autoimmune Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.