Coupling effect of tunnel ventilation and SSHPS operation strategy on the thermal environment in energy tunnels

• Developed theoretical models and a dynamic simulation system for SSHPS. • Revealed the coupling effect of tunnel ventilation and SSHPS operation. • Given a coupling operation strategy of the tunnel ventilation system and SSHPS. • Provide theoretical support for the stable regulation of tunnel thermal conditions. The subway tunnel source heat pump system (SSHPS) is one of the effective technologies for addressing the thermal pollution problem in subway tunnels. However, existing studies have focused solely on analyzing the system performance of SSHPS, with insufficient attention given to the impact of its coupled operation with the tunnel ventilation system on the thermal environment within the tunnel. This study developed a simulation system for the SSHPS based on a pilot project. The coupling effects of the SSHPS operational strategy and tunnel ventilation rate on the thermal environment within the tunnel were systematically analyzed. The results indicate that increasing tunnel ventilation during the cooling season can partially alleviate the elevated temperatures caused by SSHPS operation, although the cooling effect is limited. Conversely, reducing ventilation during the heating season can effectively prevent tunnel temperatures from exceeding the threshold caused by SSHPS operation. Furthermore, the implementation of a strategy involving the year-round continuous operation of SSHPS, in conjunction with variable air volume control within the tunnel, allows for a more flexible and effective control of the tunnel thermal environment. This study establishes a theoretical foundation and provides technical references for ensuring the long-term thermal stability of the subway energy tunnel's thermal environment.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2026-02-05
DOI
https://doi.org/10.1016/j.rineng.2026.109454
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coupling effect of tunnel ventilation and SSHPS operation strategy on the thermal environment in energy tunnels

Yifan Sun, Zhen Tong, Shimin Liang, Xiang Guo et al.
Results in Engineering
Geothermal Energy Systems and Applications
article

Coupling effect of tunnel ventilation and SSHPS operation strategy on the thermal environment in energy tunnels

Yifan Sun, Zhen Tong, Shimin Liang, Xiang Guo, Yongming Ji, Jinfu Zheng, Songtao Hu, Chengkang Yang
article en

Abstract

• Developed theoretical models and a dynamic simulation system for SSHPS. • Revealed the coupling effect of tunnel ventilation and SSHPS operation. • Given a coupling operation strategy of the tunnel ventilation system and SSHPS. • Provide theoretical support for the stable regulation of tunnel thermal conditions. The subway tunnel source heat pump system (SSHPS) is one of the effective technologies for addressing the thermal pollution problem in subway tunnels. However, existing studies have focused solely on analyzing the system performance of SSHPS, with insufficient attention given to the impact of its coupled operation with the tunnel ventilation system on the thermal environment within the tunnel. This study developed a simulation system for the SSHPS based on a pilot project. The coupling effects of the SSHPS operational strategy and tunnel ventilation rate on the thermal environment within the tunnel were systematically analyzed. The results indicate that increasing tunnel ventilation during the cooling season can partially alleviate the elevated temperatures caused by SSHPS operation, although the cooling effect is limited. Conversely, reducing ventilation during the heating season can effectively prevent tunnel temperatures from exceeding the threshold caused by SSHPS operation. Furthermore, the implementation of a strategy involving the year-round continuous operation of SSHPS, in conjunction with variable air volume control within the tunnel, allows for a more flexible and effective control of the tunnel thermal environment. This study establishes a theoretical foundation and provides technical references for ensuring the long-term thermal stability of the subway energy tunnel's thermal environment.

Results in EngineeringVol. 29
Qingdao University (CN), Qingdao University of Science and Technology (CN), Qingdao Municipal Hospital (CN), National Institute of Clean and Low-Carbon Energy (CN)
Affordable and clean energy
Openalex Percentile: Top 66%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.