Form factor meets function: anatomy-dependent electrode-skin coupling and signal content in consumer eyewear EEG systems

<i>Objective</i>. To evaluate the influence of head morphology on the performance of a wearable setup that incorporates the constraints of an eyewear-electroencephalography (EEG) device suitable for consumer-level applications. Specifically, the study aimed to characterize the electrode-skin impedance of two dry-electrode types mounted on eyeglass frames, assess the system's ability to capture alpha-rhythm modulation during eyes-open and eyes-closed (EOEC) states in the temporal region, and its capability to detect auditory event-related potentials (P300).<i>Approach</i>. A prototype was built by embedding four EEG electrodes, two gold-plated retractile pins (GPR) and two conductive elastomer (CoE), into a commercial eyeglass frame, with reference and bias on the nose pads. Signals were acquired using an OpenBCI Cyton board (ADS1299 analog front end, sampling at 256 Hz). Twenty young healthy adults underwent three experimental protocols, namely electrode-skin contact assessment, EOEC tasks (two cycles of 2 min each) to examine alpha-band (8-12 Hz) power changes and compute an alpha-to-broadband power ratio, and an auditory oddball paradigm (80% standard, 20% odd stimuli, 50 odd trials) to elicit and analyze P300 components.<i>Main results</i>. GPR electrodes exhibited moderately higher median impedance but slightly narrower confidence intervals compared to CoE electrodes. Head breadth significantly affected GPR impedance (≈11.7%decrease per mm increase), but had no significant effect on CoE impedance. Alpha-band power increased significantly during eyes-closed periods across subjects and electrode types. P300 responses (positive deflection at 300 ms) were reliably detected, with GPR electrodes yielding tighter latency distributions.<i>Significance</i>. These findings emphasize the importance of careful design considerations in wearable-EEG to account for inter-subject head anatomy variability and demonstrate that eyeglass-integrated EEG, can reliably capture both evoked and spontaneous neural responses.

Authors

Institutions

Publication Details

Journal
Journal of Neural Engineering
Published
2026-02-01
DOI
https://doi.org/10.1088/1741-2552/ae4271
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Form factor meets function: anatomy-dependent electrode-skin coupling and signal content in consumer eyewear EEG systems

Niccolò Antonello, Andrea Farabbi, Pietro Cerveri, Diana Trojaniello et al.
Journal of Neural Engineering
EEG and Brain-Computer Interfaces
article

Form factor meets function: anatomy-dependent electrode-skin coupling and signal content in consumer eyewear EEG systems

Niccolò Antonello, Andrea Farabbi, Pietro Cerveri, Diana Trojaniello, Matteo Rossi, Andrea Costanzo Palmisciano, Luca T Mainardi
article en

Abstract

<i>Objective</i>. To evaluate the influence of head morphology on the performance of a wearable setup that incorporates the constraints of an eyewear-electroencephalography (EEG) device suitable for consumer-level applications. Specifically, the study aimed to characterize the electrode-skin impedance of two dry-electrode types mounted on eyeglass frames, assess the system's ability to capture alpha-rhythm modulation during eyes-open and eyes-closed (EOEC) states in the temporal region, and its capability to detect auditory event-related potentials (P300).<i>Approach</i>. A prototype was built by embedding four EEG electrodes, two gold-plated retractile pins (GPR) and two conductive elastomer (CoE), into a commercial eyeglass frame, with reference and bias on the nose pads. Signals were acquired using an OpenBCI Cyton board (ADS1299 analog front end, sampling at 256 Hz). Twenty young healthy adults underwent three experimental protocols, namely electrode-skin contact assessment, EOEC tasks (two cycles of 2 min each) to examine alpha-band (8-12 Hz) power changes and compute an alpha-to-broadband power ratio, and an auditory oddball paradigm (80% standard, 20% odd stimuli, 50 odd trials) to elicit and analyze P300 components.<i>Main results</i>. GPR electrodes exhibited moderately higher median impedance but slightly narrower confidence intervals compared to CoE electrodes. Head breadth significantly affected GPR impedance (≈11.7%decrease per mm increase), but had no significant effect on CoE impedance. Alpha-band power increased significantly during eyes-closed periods across subjects and electrode types. P300 responses (positive deflection at 300 ms) were reliably detected, with GPR electrodes yielding tighter latency distributions.<i>Significance</i>. These findings emphasize the importance of careful design considerations in wearable-EEG to account for inter-subject head anatomy variability and demonstrate that eyeglass-integrated EEG, can reliably capture both evoked and spontaneous neural responses.

Journal of Neural EngineeringVol. 23(1)
University of Pavia (IT), Luxottica (Italy) (IT), Politecnico di Milano (IT)
Openalex Percentile: Top 65%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.