A Pilot Three-Dimensional Evaluation of Acetabular Bony Coverage After Modified Spitzy Shelf Acetabuloplasty

Modified Spitzy shelf acetabuloplasty is a joint-preserving surgical procedure for acetabular dysplasia that aims to enhance bony coverage of the hip joint. Although prior studies have primarily relied on two-dimensional (2D) radiographic evaluations, comprehensive three-dimensional (3D) assessments remain limited. The purpose of this retrospective study was to evaluate changes quantitatively in acetabular coverage following modified Spitzy shelf acetabuloplasty using 3D models reconstructed from computed tomography (CT) images. We retrospectively analyzed 11 hips in 11 patients who underwent staged bilateral modified Spitzy shelf acetabuloplasty. Preoperative and postoperative CT data were used to construct 3D pelvic models, which were registered using anatomical landmarks. Bone graft dimensions, insertion angle, and placement location were evaluated. Acetabular sector angles (ASA), representing circumferential coverage of the femoral head, were measured at 15° intervals on the functional pelvic plane and the anterior pelvic plane. The mean bone graft dimensions were 26.3 ± 3 mm (anteroposterior length) and 12.7 ± 2.7 mm (mediolateral length), providing coverage of 49.5° ± 9.1°. Postoperative ASA increased significantly from 34.5° to 60° on the functional pelvic plane and from 0° to 45° on the anterior pelvic plane (both <i>p</i> < 0.05). 3D analysis demonstrated that modified Spitzy shelf acetabuloplasty effectively enhanced anterosuperior acetabular bony coverage. Although this is a report of a few cases (11 hips), the above findings highlight the value of 3D evaluation in identifying postoperative changes that may not be detected using conventional 2D assessments. Also, further research analyzing the three-dimensional bone graft model revealed in this study may help inform the development of a more ideal biomimetic approach, not only in terms of shape but also function.

Authors

Institutions

Publication Details

Journal
Biomimetics
Published
2026-02-05
DOI
https://doi.org/10.3390/biomimetics11020117
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Pilot Three-Dimensional Evaluation of Acetabular Bony Coverage After Modified Spitzy Shelf Acetabuloplasty

Shohei Sogawa, Takehito Hananouchi, Fumito Kobayashi, T. Saito et al.
Biomimetics
Orthopaedic implants and arthroplasty
article

A Pilot Three-Dimensional Evaluation of Acetabular Bony Coverage After Modified Spitzy Shelf Acetabuloplasty

Shohei Sogawa, Takehito Hananouchi, Fumito Kobayashi, T. Saito, Kenichi Oe, Tomohisa Nakamura
article en

Abstract

Modified Spitzy shelf acetabuloplasty is a joint-preserving surgical procedure for acetabular dysplasia that aims to enhance bony coverage of the hip joint. Although prior studies have primarily relied on two-dimensional (2D) radiographic evaluations, comprehensive three-dimensional (3D) assessments remain limited. The purpose of this retrospective study was to evaluate changes quantitatively in acetabular coverage following modified Spitzy shelf acetabuloplasty using 3D models reconstructed from computed tomography (CT) images. We retrospectively analyzed 11 hips in 11 patients who underwent staged bilateral modified Spitzy shelf acetabuloplasty. Preoperative and postoperative CT data were used to construct 3D pelvic models, which were registered using anatomical landmarks. Bone graft dimensions, insertion angle, and placement location were evaluated. Acetabular sector angles (ASA), representing circumferential coverage of the femoral head, were measured at 15° intervals on the functional pelvic plane and the anterior pelvic plane. The mean bone graft dimensions were 26.3 ± 3 mm (anteroposterior length) and 12.7 ± 2.7 mm (mediolateral length), providing coverage of 49.5° ± 9.1°. Postoperative ASA increased significantly from 34.5° to 60° on the functional pelvic plane and from 0° to 45° on the anterior pelvic plane (both <i>p</i> < 0.05). 3D analysis demonstrated that modified Spitzy shelf acetabuloplasty effectively enhanced anterosuperior acetabular bony coverage. Although this is a report of a few cases (11 hips), the above findings highlight the value of 3D evaluation in identifying postoperative changes that may not be detected using conventional 2D assessments. Also, further research analyzing the three-dimensional bone graft model revealed in this study may help inform the development of a more ideal biomimetic approach, not only in terms of shape but also function.

BiomimeticsVol. 11(2)
Hiroshima University (JP), Kansai Medical University (JP), Hiroshima University Hospital (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 65%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.