Characterizing the Oscillatory Unstart/Restart of a Supersonic Stator in Unsteady Conditions
This paper presents a numerical investigation of an undesirable mode of unsteady supersonic turbine operation that may arise under off-design conditions. Two-dimensional unsteady Reynolds-averaged Navier–Stokes simulations of a supersonic stator operating in unsteady conditions were performed to characterize the oscillatory unstart/restart behavior that was observed in cases where inlet Mach numbers fluctuated between the unstarted and self-started conditions of the stator. Oscillatory unstart/restart at higher reduced frequencies corresponded to shorter unstart/restart durations, which resulted in lower stator total pressure losses and higher outlet tangential velocities. It was observed that supersonic stator operation at sufficiently high reduced frequencies resulted in a mitigation of unstarting in unsteady conditions.
Authors
- Jiun-Ming Li
- Melanie Ng
- Chiang Juay Teo
Institutions
- National University of Singapore (SG)
Publication Details
- Journal
- Journal of Propulsion and Power
- Published
- 2026-01-21
- DOI
- https://doi.org/10.2514/1.b40064
- Primary Topic
- Turbomachinery Performance and Optimization
- Type
- article
- Field-Weighted Citation Impact
- 0.00