Building Information Modelling, flood mitigation, technology adoption, urban resilience, construction industry

The insulation performance of building envelopes is one of the areas with a significant impact on the building energy intensity. In Poland, 71 % of the energy demand of the entire building is used for heating households. Therefore, solutions are sought that will ensure the required thermal comfort and reduce the energy demand. The paper presents the testing of the temper- ature distribution inside an envelope made of structural insulated panels (SIPs) using state- -of-the art FBG sensors. Compared to classic temperature measuring devices, FBG sensors are characterized by high measuring resolution and reliability, reducing the testing invasiveness to the minimum. A composite structural insulated panel (SIP) and a traditional two-layer wall were tested. SIPs are modern building materials that are both a structural and an insulating element of building envelopes. The three-layer structure consists of a light core (EPS) skinned on both sides with magnesite boards which provide the panel with high strength, rigidity, fire resistance and resistance to biological corrosion. The knowledge of the actual temperature distribution inside the envelope can significantly improve the control of heating systems in buildings and reduce energy consumption.

Authors

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-12-01
DOI
https://doi.org/10.17512/bozpe.2025.14.25
Primary Topic
Building energy efficiency and sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Building Information Modelling, flood mitigation, technology adoption, urban resilience, construction industry

Mateusz Płonka, Anna Satława, Janusz Juraszek, Maciej Famulok
SHILAP Revista de lepidopterología
Building energy efficiency and sustainability
article

Building Information Modelling, flood mitigation, technology adoption, urban resilience, construction industry

Mateusz Płonka, Anna Satława, Janusz Juraszek, Maciej Famulok
article en

Abstract

The insulation performance of building envelopes is one of the areas with a significant impact on the building energy intensity. In Poland, 71 % of the energy demand of the entire building is used for heating households. Therefore, solutions are sought that will ensure the required thermal comfort and reduce the energy demand. The paper presents the testing of the temper- ature distribution inside an envelope made of structural insulated panels (SIPs) using state- -of-the art FBG sensors. Compared to classic temperature measuring devices, FBG sensors are characterized by high measuring resolution and reliability, reducing the testing invasiveness to the minimum. A composite structural insulated panel (SIP) and a traditional two-layer wall were tested. SIPs are modern building materials that are both a structural and an insulating element of building envelopes. The three-layer structure consists of a light core (EPS) skinned on both sides with magnesite boards which provide the panel with high strength, rigidity, fire resistance and resistance to biological corrosion. The knowledge of the actual temperature distribution inside the envelope can significantly improve the control of heating systems in buildings and reduce energy consumption.

SHILAP Revista de lepidopterología
University of Bielsko-Biała (PL)
Affordable and clean energy
Openalex Percentile: Top 32%
Building energy efficiency and sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.