Lateral performance of plywood-sheathed cold-formed steel shear wall: Experimental and numerical investigations

Plywood, as an engineered wood product, offers excellent mechanical properties and cost-effectiveness, making it a promising sheathing candidate for cold-formed steel (CFS) shear walls. However, limited research has hindered its application compared to other sheathing materials. This paper presents a comprehensive experimental and numerical investigation into the lateral performance of plywood-sheathed CFS shear walls. Fifteen full-scale specimens were tested to evaluate the effects of sheathing thickness, perimeter screw spacing, screw diameter, and loading protocol. For a configuration with 2.44 × 2.44 m size, 12 mm sheathing, 4.8 mm screws, and 150 mm perimeter screw spacing, the wall exhibited an elastic stiffness of 1.47 kN/mm and a shear strength of 16.1 kN/m. Results indicate that shear performance is governed by connection behavior. Densifying perimeter screws to 50 mm significantly enhanced shear capacity but may lead to a reduction in ductility if the framing is not concurrently strengthened. A detailed finite element model was developed and verified against the experimental data. A subsequent parametric study investigated the effects of stud spacing, stud section size, field screw spacing, and wall aspect ratio on wall performance. Results indicated that increasing stud spacing reduces shear capacity, whereas stud section size has negligible impact on ultimate strength under proper overstrength design, and shear strength per unit length remained relatively constant for aspect ratios up to 2:1. • Lateral performance of 15 plywood-sheathed CFS shear walls was experimentally tested. • Connection behavior, mostly screw pull-through, governs the shear performance. • Capacity design is required to ensure ductile failure in high-capacity walls. • Validated FE model reveals constant shear strength for aspect ratios up to 2:1.

Authors

Institutions

Publication Details

Journal
Journal of Constructional Steel Research
Published
2026-02-05
DOI
https://doi.org/10.1016/j.jcsr.2026.110279
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lateral performance of plywood-sheathed cold-formed steel shear wall: Experimental and numerical investigations

Zhaozhuo Gan, Zhiyang Cheng, Lie Luo, Xiaofeng Sun
Journal of Constructional Steel Research
Structural Load-Bearing Analysis
article

Lateral performance of plywood-sheathed cold-formed steel shear wall: Experimental and numerical investigations

Zhaozhuo Gan, Zhiyang Cheng, Lie Luo, Xiaofeng Sun
article en

Abstract

Plywood, as an engineered wood product, offers excellent mechanical properties and cost-effectiveness, making it a promising sheathing candidate for cold-formed steel (CFS) shear walls. However, limited research has hindered its application compared to other sheathing materials. This paper presents a comprehensive experimental and numerical investigation into the lateral performance of plywood-sheathed CFS shear walls. Fifteen full-scale specimens were tested to evaluate the effects of sheathing thickness, perimeter screw spacing, screw diameter, and loading protocol. For a configuration with 2.44 × 2.44 m size, 12 mm sheathing, 4.8 mm screws, and 150 mm perimeter screw spacing, the wall exhibited an elastic stiffness of 1.47 kN/mm and a shear strength of 16.1 kN/m. Results indicate that shear performance is governed by connection behavior. Densifying perimeter screws to 50 mm significantly enhanced shear capacity but may lead to a reduction in ductility if the framing is not concurrently strengthened. A detailed finite element model was developed and verified against the experimental data. A subsequent parametric study investigated the effects of stud spacing, stud section size, field screw spacing, and wall aspect ratio on wall performance. Results indicated that increasing stud spacing reduces shear capacity, whereas stud section size has negligible impact on ultimate strength under proper overstrength design, and shear strength per unit length remained relatively constant for aspect ratios up to 2:1. • Lateral performance of 15 plywood-sheathed CFS shear walls was experimentally tested. • Connection behavior, mostly screw pull-through, governs the shear performance. • Capacity design is required to ensure ductile failure in high-capacity walls. • Validated FE model reveals constant shear strength for aspect ratios up to 2:1.

Journal of Constructional Steel ResearchVol. 240
Tongji University (CN), University of Northern British Columbia (CA), University of Alberta (CA), Xiamen University (CN), Xiamen University of Technology (CN)
Openalex Percentile: Top 66%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.