Validation of a Deep-Learning Coregistration Framework for Long–Axial-Field-of-View PET/CT Using Low-Radiation-Exposure Protocols Across Various Tracers

The advent of long-axial-field-of-view (LAFOV) PET/CT systems has significantly improved whole-body imaging by providing higher sensitivity and extended torso coverage. However, PET/CT potential misalignment remains a challenge, potentially introducing artifacts and quantification errors. Moreover, PET protocols with reduced scanning duration and dose, as well as the use of ultra-low-dose CT (ULD-CT), are increasingly relevant in clinical practice and research. This study aimed to evaluate the robustness and generalizability of a deep-learning coregistration framework for PET/CT alignment using low-dose PET and ULD-CT across various tracers with a LAFOV system. <b>Methods:</b> In total, 63 scans with 4 different tracers (<sup>89</sup>Zr-trastuzumab, <sup>15</sup>O-H<sub>2</sub>O, <sup>18</sup>F-MC225, and <sup>18</sup>F-FDG) were included to assess PET and CT alignment improvements. Further evaluation was performed by comparing CT scans coregistered to the original PET images (rCT) with those coregistered to low-count (50%, 25%, and 12.5% of original counts) PET images (LC-rCT). Dice similarity coefficient, Jaccard similarity coefficient, Hausdorff distance, and average surface distance were used as evaluation metrics. Furthermore, ULD-CT coregistered to PET (rULD-CT) was compared with low-dose CT coregistered to the same PET (rLD-CT) using the same metrics. PET accuracy was evaluated by calculating SUVs. <b>Results:</b> The robustness of the deep-learning coregistration framework was demonstrated in reduced PET counts and ULD-CT scenarios across tracers. All metrics indicated robust performance when comparing LC-rCT with rCT and rULD-CT with rLD-CT. Consistent SUVs across varying PET counts and ULD-CT conditions further validated the quantitative accuracy of the approach. <b>Conclusion:</b> This work highlights that neither the use of low-dose PET protocols nor ULD-CT compromise the performance of this coregistration framework across 4 tracers. For LAFOV PET, these findings support the feasibility of such a framework in imaging protocols with reduced radiation exposure.

Authors

Institutions

Publication Details

Journal
Journal of Nuclear Medicine
Published
2026-02-05
DOI
https://doi.org/10.2967/jnumed.125.270420
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a Deep-Learning Coregistration Framework for Long–Axial-Field-of-View PET/CT Using Low-Radiation-Exposure Protocols Across Various Tracers

Joyce van Sluis, Z. Li, Joost F. Somsen, Giordana Salvi de Souza et al.
Journal of Nuclear Medicine
Medical Imaging Techniques and Applications
article

Validation of a Deep-Learning Coregistration Framework for Long–Axial-Field-of-View PET/CT Using Low-Radiation-Exposure Protocols Across Various Tracers

Joyce van Sluis, Z. Li, Joost F. Somsen, Giordana Salvi de Souza, Charalampos Tsoumpas, Andor W.J.M. Glaudemans, Laura Providência, Mostafa Roya, Gert Luurtsema, Adriaan A. Lammertsma, Samaneh Mostafapour, Adrienne H. Brouwers, Goudje L van Leeuwen, Jean-Paul P.M. de Vries, Riemer H.J.A. Slart, T. Samara Martinez-Lucio, Maurizio Conti, Rudi A.J.O. Dierckx, Paul Schleyer, Joshua Schaefferkoetter, Philipp Mohr
article en

Abstract

The advent of long-axial-field-of-view (LAFOV) PET/CT systems has significantly improved whole-body imaging by providing higher sensitivity and extended torso coverage. However, PET/CT potential misalignment remains a challenge, potentially introducing artifacts and quantification errors. Moreover, PET protocols with reduced scanning duration and dose, as well as the use of ultra-low-dose CT (ULD-CT), are increasingly relevant in clinical practice and research. This study aimed to evaluate the robustness and generalizability of a deep-learning coregistration framework for PET/CT alignment using low-dose PET and ULD-CT across various tracers with a LAFOV system. <b>Methods:</b> In total, 63 scans with 4 different tracers (<sup>89</sup>Zr-trastuzumab, <sup>15</sup>O-H<sub>2</sub>O, <sup>18</sup>F-MC225, and <sup>18</sup>F-FDG) were included to assess PET and CT alignment improvements. Further evaluation was performed by comparing CT scans coregistered to the original PET images (rCT) with those coregistered to low-count (50%, 25%, and 12.5% of original counts) PET images (LC-rCT). Dice similarity coefficient, Jaccard similarity coefficient, Hausdorff distance, and average surface distance were used as evaluation metrics. Furthermore, ULD-CT coregistered to PET (rULD-CT) was compared with low-dose CT coregistered to the same PET (rLD-CT) using the same metrics. PET accuracy was evaluated by calculating SUVs. <b>Results:</b> The robustness of the deep-learning coregistration framework was demonstrated in reduced PET counts and ULD-CT scenarios across tracers. All metrics indicated robust performance when comparing LC-rCT with rCT and rULD-CT with rLD-CT. Consistent SUVs across varying PET counts and ULD-CT conditions further validated the quantitative accuracy of the approach. <b>Conclusion:</b> This work highlights that neither the use of low-dose PET protocols nor ULD-CT compromise the performance of this coregistration framework across 4 tracers. For LAFOV PET, these findings support the feasibility of such a framework in imaging protocols with reduced radiation exposure.

Journal of Nuclear Medicine
University Medical Center Groningen (NL), University of Groningen (NL), University of Twente (NL)
Openalex Percentile: Top 66%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.